Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.4.21.4 (trypsin)
42,187 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Fractions of three trypsin-like proteinases, TL I, TL II, and TL III, a chymotrypsin-like proteinase, CL, two carboxypeptidase A enzymes, CPA I and CPA II and two carboxypeptidase B enzymes, CPB I and CPB II, from Antarctic krill (Euphausia superba) have been characterized with respect to purity by the means of capillary electrophoresis, CE, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The masses of the trypsin-like and chymotrypsin-like proteinases were determined to be 25,020, 25,070, 25,060, and 26,260Da for TL I, TL II, TL III, and CL, respectively. The masses of the CPA enzymes are likely 23,170 and 23,260Da, whereas the CPB enzyme masses likely are 33,730 and 33,900Da. The degradation efficiency and cleavage pattern of the trypsin-like proteinases were studied with native myoglobin as a model substrate using CE, MALDI-TOF-MS, and nanoelectrospray mass spectrometry (nESI-MS). The degradation efficiency of the trypsin-like proteinases was found to be approximately 12 and 60 times higher compared to bovine trypsin at 37 degrees C and 1-3 degrees C, respectively. All three fractions of trypsin-like proteinases showed a carboxypeptidase activity in combination with their trypsin activity.
...
PMID:Characterization of proteinases from Antarctic krill (Euphausia superba). 1235 83

Accelerated proteolytic cleavage of proteins under controlled microwave irradiation has been achieved. Selective peptide fragmentation by endoproteases trypsin or lysine C led to smaller peptides that were analyzed by matrix-assisted laser desorption ionization (MALDI) or liquid chromatography-electrospray ionization (LC-ESI) techniques. The efficacy of this technique for protein mapping was demonstrated by the mass spectral analyses of the peptide fragmentation of several biologically active proteins, including cytochrome c, ubiquitin, lysozyme, myoglobin, and interferon alpha-2b. Most important, using this novel approach digestion of proteins occurs in minutes, in contrast to the hours required by conventional methods.
...
PMID:Microwave-enhanced enzyme reaction for protein mapping by mass spectrometry: a new approach to protein digestion in minutes. 1238 49

Proteolytic digestion is an important step in protein identification by peptide mass mapping and tandem mass spectrometry (MS/MS)-based peptide sequencing. Traditional methods of protein digestion require extended incubation times and have difficulty with proteolytically resistant proteins. Here, we describe a method in which a protein solution was combined with a mixed aqueous-organic solution (methanol, isopropanol, or acetonitrile) and passed through a microcolumn containing immobilized trypsin. Myoglobin sequence coverage was high (>85%) in all three solvents, and differences in spectra were seen among the different solution conditions. Notably, methanol-based digestions produced fewer missed cleavages while acetonitrile-based digestions produced the most peptides and the most intense mass spectra. Flow rates through the column were varied from 0.5 to 15 micro L/min, corresponding to column residence times of 78 and 2.6 s, respectively. All flow rates produced high sequence coverage of myoglobin, although, at higher flow rates, more missed cleavages were observed. No significant increase in undigested myoglobin was observed with flow rates up to 15 micro L/min. The described method was applied to the digestion of human transferrin (hTf), a proteolytically resistant protein. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis detected 42 peptides covering 46% of the hTf sequence. The traditional aqueous method resulted in 12 peptides (8% sequence coverage) only when high concentrations of trypsin were used. Lastly, digestion of low nanomolar myoglobin was shown to produce detectable peptides and resulted in a correct database hit. Thus, we demonstrate a method that is capable of rapid on-line digestion, thereby lending itself to high-throughput identification of proteins.
...
PMID:On-column digestion of proteins in aqueous-organic solvents. 1272 Feb 84

Isolelectric focusing (IEF) of proteins on immobilized pH gradient (IPG) strips is an integral part of two-dimensional (2D) electrophoresis-based proteomics. Proteins can be effectively analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) on the intact strip itself, leading to the creation of a virtual 2D map giving pI and MW information, bypassing the second dimension SDS-PAGE. Further, trypsin digestion of proteins on the strip can significantly aid the identification of IPG-separated proteins. However, the small size of the peptides leads to diffusion along and outside the gel matrix. In this study, we describe a simple spray-based procedure to perform 'on-strip' trypsin digestion of proteins embedded in IPG strips. Examination of intact myoglobin and its tryptic peptides shows that post-digestion diffusion of tryptic peptides is significantly minimized using this approach.
...
PMID:Trypsin digestion of proteins on intact immobilized pH gradient strips for surface matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis. 1455 33

Microfluidic devices with a dual function containing both a solid-phase extractor and an enzymatic microreactor have been prepared, and their operation has been demonstrated. The devices were fabricated from a 25-mm-long porous poly(butyl methacrylate-co-ethylene dimethacrylate) monolith prepared within a 50-microm-i.d. capillary. This capillary with a pulled 9-12-microm needle tip was used as a nanoelectrospray emitter coupling the device to a mass spectrometer. Photografting with irradiation through a mask was then used to selectively functionalize a 20-mm-long portion of the monolith, introducing reactive poly(2-vinyl-4,4-dimethylazlactone) chains to enable the subsequent attachment of trypsin, thereby creating an enzymatic microreactor with high proteolytic activity. The other 5 mm of unmodified hydrophobic monolith served as micro solid-phase extractor (microSPE). The dual-function devices were used in two different flow directions; concentration of myoglobin that was absorbed from its dilute solution, followed by elution and digestion or digestion, followed by concentration. Operations in both directions afforded equal sequence coverage. Different volumes of myoglobin solution ranging from 2 to 20 microL were loaded on the device. Very high sequence coverages of almost 80% were achieved for the highest loading. Despite the very short length of the extractor unit, the device operated in the digest-solid-phase extraction direction also enabled the separation of peaks that mostly contained undigested protein and peptides.
...
PMID:Dual-function microanalytical device by in situ photolithographic grafting of porous polymer monolith: integrating solid-phase extraction and enzymatic digestion for peptide mass mapping. 1471 Aug 9

Peptide mass fingerprinting (PMF) is a powerful technique in which experimentally measured m/z values of peptides that result from a protein digest form the basis for a characteristic fingerprint of the intact protein. Due to its propensity to generate singly-charged ions, along with its relative insensitivity to salts and buffers, matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) is the MS method of choice for PMF. The qualitative features of a MALDI-MS mass spectrum can be selectively tuned by varying the matrix and the solvent system used to prepare the matrix. The selective tuning of MALDI-MS mass spectra in order to optimize PMF results is addressed in this paper. Carbonic anhydrase, hemoglobin alpha- and beta-chain, and myoglobin were digested with trypsin, and the digest was analyzed with MALDI-MS. 2,5-Dihydroxybenzoic acid (2,5-DHB) and alpha-cyano-4-hydroxycinnamic acid were prepared, using five different solvent systems: (A) 99% acetone; (B) 50% acetonitrile (ACN), 0.1% trifluoroacetic acid (TFA); (C) 75% ACN, 0.1% TFA; (D) formic acid:H(2)O: 2-propanol (1:3:2); and (E) H(2)O:MeOH (2:1). Each protein was found to have a different optimum solvent system for PMF. Generally, better PMF results were obtained with 2,5-DHB. The best PMF results were obtained when all of the mass spectral data for a particular protein digest were convolved.
...
PMID:A strategy to improve peptide mass fingerprinting matches through the optimization of matrix-assisted laser desorption/ionization matrix selection and formulation. 1476 Jul 19

Proteomics and peptidomics could benefit from simple methods for high-resolution separation of oligopeptides analogous to slab gel electrophoresis of proteins. Gels of Pluronic F127 copolymer surfactant were investigated as media for slab gel electrophoresis of oligopeptides using a trypsin digest of myoglobin. Concentrated solutions of Pluronic F127 are fluid at low temperatures (</= 5 degrees C), but become a gel-like micellar liquid crystal upon warming. Nucleic acids are well separated by electrophoresis in these gels as previously shown by Rill and Liu. Good separations of myoglobin tryptic peptides were accomplished by electrophoresis on slab gels of 24% Pluronic F127 or 15% polyacrylamide using the alkaline Laemmli buffer system (without sodium dodecyl sulfate). Labeling of peptides with the succinimidyl ester of Cascade Yellow (CY) prior to electrophoresis allowed sensitive detection with blacklight illumination at 365 nm. Labeled tryptic peptides were identified by matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF)-mass spectrometry. An inverse dependence of electrophoretic mobility on mass of peptides with charge Z = -1 was observed in both media. Two-dimensional (2-D) electrophoresis of myoglobin peptides on polyacrylamide, then on Pluronic media, at pH 8.3 indicated that the primary separation mechanism of most peptides was the same in both media. A few off-diagonal spots indicated that some peptides were preferentially retarded in Pluronic gels, perhaps due to hydrophobic effects. The ease of gel preparation and peptide recovery are advantages of Pluronic F127 gels for oligopeptide electrophoresis. The two media can be combined conveniently for 2-D electrophoresis, providing means to facilitate protein identification and peptidomics.
...
PMID:Peptide separations by slab gel electrophoresis in pluronic F127 polymer liquid crystals. 1517 45

A new transition metal-based reaction has been developed for the selective modification of tryptophan residues on protein substrates. After activation of vinyl-substituted diazo compounds by Rh2(OAc)4, the resulting metallocarbenoid intermediates were found to modify indoles in aqueous media despite competing reactions with water. Both N- and 2-substituted indole products were observed in the reaction. Following initial small-molecule studies, the reaction was performed on two protein substrates. Both myoglobin and subtilisin Carlsberg were modified readily in aqueous solution, and the tryptophan selectivity of the reactions was confirmed through MS analyses of trypsin digest fragments. It was also demonstrated that myoblobin concentrations as low as 10 muM still led to appreciable levels of modification. Reconstitution experiments confirmed that myoglobin retained its ability to bind heme following modification.
...
PMID:Selective tryptophan modification with rhodium carbenoids in aqueous solution. 1531 33

The preparation and characterization of a new trypsin-based bioreactor is here described for on-line protein digestion and peptide analysis. Trypsin was immobilized on an epoxy-modified silica monolithic support with a single reaction step and the amount of immobilized enzyme was found to be 66.07 mg (+/-11.75 S.D.)/column (n = 6). The bioreactor was coupled through a switching valve to an analytical column for the on-line digestion, peptide separation and identification of test proteins by ESI-MS-MS. The influence of various parameters (flow rate, temperature, buffer pH and molarity, etc.) on enzymatic activity was investigated by an experimental design and the mostly significant factor was found to be the flow rate. The efficacy of the reported on-line bioreactor for tryptic mapping is reported for somatostatin and myoglobin, selected as model compounds. Tryptic peptide maps obtained by on-line digestion of myoglobin were compared to those obtained by traditional off-line digestion. Sequence coverage obtained with the on-line protocol (21 peptides, 75.16% coverage of myoglobin sequence) was found to be comparable to the one obtained with the off-line protocol (18 peptides, 76.47% coverage). Sensitivity for myoglobin digestion and identification was 0.1 mg/ml. The reproducibily of the peptide maps in terms of retention time was from 1.53 to 4.31%, R.S.D.
...
PMID:Development of a bioreactor based on trypsin immobilized on monolithic support for the on-line digestion and identification of proteins. 1537 84

Losses of proteolytic peptides during extraction and/or purification procedures succeeding in-gel or in-solution digests of proteins frequently occur in the course of protein identification investigations. In order to overcome this disadvantage, the method of in-capillary digest was developed: native proteins were incubated in the presence of endoproteases in the electrospray capillary and the resulting peptides were analyzed by nanoelectrospray-mass spectrometry during the ongoing proteolysis. In-capillary digest of apomyglobin by use of trypsin in a molar ratio of 25:1 yielded complete degradation already after 15 min. The sequence coverage based on formation of molecular ions was 100% and peptide ions could be fragmented by collision-induced dissociation and sequenced. When myoglobin was incubated in the electrospray capillary with trypsin in a molar ratio of 500:1, a clear shift from molecular ions and miscleaved peptide ions to the expected final tryptic peptide ions was observed over a 2 h period. The peptide spectra obtained from tryptic in-capillary proteolysis of bovine serum albumin and apotransferrin, respectively, gave rise to sequence coverages of more than 40% for both proteins. The data obtained from the peptide maps as well as from collision-induced dissociation (CID) of selected peptides were more than sufficient for protein identification by database searches. An elephant milk protein preparation was used to demonstrate the application of in-capillary proteolysis on protein mixtures. Tryptic digest, simultaneous analysis of the proteolytic peptides by use of CID, and subsequent sequencing allowed the identification of lactoferrin, alphas1-casein, beta-casein, delta-casein, and kappa-casein by homology search.
...
PMID:High sequence coverage by in-capillary proteolysis of native proteins and simultaneous analysis of the resulting peptides by nanoelectrospray ionization-mass spectrometry and tandem mass spectrometry. 1576 58


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>