Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.4.21.37 (neutrophil elastase)
4,078 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The serum levels of endotoxin, polymorphonuclear leukocyte elastase (PMN-E), and the coagulation and fibrinolytic markers (D-dimer, TAT) were measured in the patients with esophageal cancer, lung cancer, and benign pulmonary tumors before and after the operation; on the day of operation, and the 1st, 3rd, and 7th postoperative day. The biological responses of the patients under surgical stress were evaluated. In the patients without complications, the endotoxin levels measured by the Toxicolor method and the PMN-E levels did show any significant increase in the early postoperative period, and they returned to the normal levels by the 7th postoperative day. On the contrary, in the patients with postoperative complications, they continued to increase throughout the study period. The endotoxin levels measured by the Endospacy test did not show any significant changes postoperatively. The D-dimer and TAT levels showed their highest values on the first postoperative day. The serum levels of endotoxin, PMN-E, and molecular markers of the coagulation and fibrinolytic system in the patients under surgical stress may be useful factors in predicting the postoperative outcome.
...
PMID:[Alteration of serum levels of endotoxin, polymorphonuclear leukocyte elastase, and the molecular markers of the coagulation and fibrinolytic system in the patients with esophageal cancer and lung cancer before and following operation]. 774 28

In this article, the clinical experience with a cardiopulmonary bypass (CPB) using a newly developed hollow fiber oxygenator with an ultra-thin layer of silicone is reported. A comparative study of biocompatibility between the new oxygenator and a heparin coated oxygenator is also described. The CPB was performed with a silicone coated oxygenator, Mera Excelung Binding Prim HPO 15 H-C (Group I, n = 6) or Binding Prim HPO 25 H-C (Group II, n = 10) (Senko Medical Instrument Mfg., Tokyo, Japan). Air could be vented through the silicone coated hollow fibers, and it was easy to prime the circuits. The CPB duration was 101 +/- 37 min and 170 +/- 64 min for Groups I and II, respectively. There were no deaths and no complications from CPB. Partial arterial pressure of O2 levels 60 minutes after the start of CPB were 529 +/- 28 mm Hg and 529 +/- 28 mmHg for Group I and II, respectively. Partial arterial pressure of CO2 levels 60 min after the start of CPB were 36.4 +/- 4.6 mmHg and 39.4 +/- 4.4 mmHg, respectively. Plasma free hemoglobin at 60 min was 33.5 +/- 17.2 mg/ dL and 46.7 +/- 26.1 mg/dL for Groups I and II, respectively. As an evaluation of biocompatibility, the effects of the new oxygenator on platelet activation (GP Ib, IIb/IIIa), coagulation (TAT), fibrinolysis (PIC), and inflammatory response (C3a, granulocyte elastase) were investigated during CPB and comparing to those of the heparin coated oxygenator. There were no significant differences in GP Ib, GP IIb/IIa, TAT, PIC, and granulocyte elastase between the two oxygenators. However, 60 min after the start of CPB, the C3a was significantly lower for the new oxygenator group than for the heparin coated oxygenator group (p < 0.03). The new oxygenator showed good gas transfer, low hemolysis, and good biocompatibility. Because of its durability and good biocompatibility, the new oxygenator was determined to be suitable for prolonged extra corporeal circulation.
...
PMID:Clinical evaluation of a silicone coated hollow fiber oxygenator. 936 Jan 43

The material and the surface patterns of intravascular stents play a pivotal role in activating platelets and triggering adherence of inflammatory cells that consecutively leads to renarrowing caused by neointimal hyperplasia. To improve these features, besides mechanical and chemical modifications, ways of masking the stent by covering have been developed. In addition, polymer-coated stents are used as vehicle for local drug delivery. But as substances used for this application are described to possess an inflammatory potential, this aspect has to be evaluated. In the present study we compared different approaches to surface alterations applied to a nitinol stent design. Besides commonly used techniques like passivation and electropolishing, we evaluated coatings with heparin, aluminium and a polyurethane polymer regarding their thrombogenic and inflammatory characteristics. By weaving thin elastomer fibres a graft was generated. The previously described Chandler loop was used to simulate arterial flow conditions ex vivo using rotating PVC tubings filled with human blood. All stents received 120 min of blood contact. To determine thrombocyte activation and inflammatory reaction, the platelet count and levels of beta-TG, TAT and PMN-elastase were assessed. Scanning electron microscopy was used to visualize the reactions. Mechanical polishing and passivation did not improve the stent surface characteristics while sandblasting, electropolishing and aluminium covering decreased activation of the coagulation cascade. In terms of thrombogenicity, the heparin coating had no beneficial effect. The lowest thrombogenic potential was found in the Polyurethane-coated stent group. All stents showed similar levels of polymorph nuclear granulocyte elastase except for the membrane design. While mechanical and chemical modifications are able to reduce thrombogenicity, coating with this particular polyurethane polymer seems to be superior to these approaches regarding the parameters assessed in this experimental setting. The Chandler loop is a valuable tool to test polymeric coatings ex vivo since these modifications may reduce drug performance by inducing inflammatory reaction themselves.
...
PMID:Reduced thrombogenicity of nitinol stents--in vitro evaluation of different surface modifications and coatings. 1609 86