Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:3.2.1.36 (
hyaluronidase
)
4,606
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Three lysosomal polysaccharidases were measured in synovial fluid (SF) and serum from rheumatoid (RA) patients, SF from osteoarthritic (OA) patients, and serum from healthy volunteers. (1) There was no correlation between the enzyme levels and
white cell
counts in the SF. (2) beta-glucuronidase and beta-N-acetylglucosaminidase were markedly elevated in the SF of RA as compared to OA. (3) beta-glucuronidase and beta-N-acetylglucosaminidase levels in the SF of RA correlated well with each other but not with
hyaluronidase
. (4) beta-glucuronidase and beta-N-acetylglucosaminidase levels were higher in the SF of RA than in the corresponding serum, while the converse was true for
hyaluronidase
. (5) Hyaluronidase levels were significantly higher in RA serum than in normal serum. These results suggest that the synovial membrane may be the source of beta-glucuronidase and beta-N-acetylglucosaminidase, while
hyaluronidase
is derived from a source remote from the joint via the serum. This source of
hyaluronidase
may be the liver. (J Rheumatol 2: 393-400, 1975).
...
PMID:The origins and relative distribution of polysaccharidases in rheumatoid and osteoarthritic fluids. 120 71
A 70-year-old woman previously exposed to
hyaluronidase
during ophthalmic surgery had excision of hypertrophic bulbar conjunctival tissue in the right eye. Hyaluronidase was added to the peribulbar anesthetic agent. Five days postoperatively, the patient presented with proptosis in the right eye, extraocular muscle restriction, and decreased visual acuity. She was apyrexial with a normal
white cell
count; computed tomography of the orbits showed a diffuse increase in soft tissue density. Clinical features were unchanged after 24 hours of intravenous antibiotics, but subsequent administration of high-dose oral steroids led to clinical improvement.
...
PMID:Hyaluronidase allergy after peribulbar anesthesia with orbital inflammation. 1612 69
Classification of body cavity effusions is an important step in the investigation and diagnosis of disease in cats. Feline inflammatory effusions are often highly proteinaceous and viscous, which can cause clumping of white cells and subsequently inaccurate nucleated cell counts (NCCs) using automated and manual methods. Microscopic assessment of cellularity can also be difficult given the variable thickness of smears and cell clumping, which skews
white cell
distribution. The ADVIA 120 uses 2
white cell
-counting channels, the basophil/lobularity (WBC/baso) and differential/peroxidase channels, which can provide quite different results in highly viscous feline samples and often disagree with smear assessment of cellularity. We investigated the effects of pre-incubation of feline effusion samples with
hyaluronidase
and its effects on NCCs and cellularity assessment. NCCs were obtained by automated analysis using the ADVIA 120 and by manual counting methods. Agreement was assessed using a Bland-Altman chart. Pretreatment of samples with
hyaluronidase
resulted in good agreement between the ADVIA basophil channel and manual counting methods in all samples in the study. However, improvements in NCCs after
hyaluronidase
treatment were significantly greater in clumped samples, and cell distribution of these samples on direct smears was also improved. Therefore, when nucleated cell clumping is observed on a direct smear, pretreatment of the sample with
hyaluronidase
prior to analysis on an automated analyzer is advised, with the WBC/baso channel displaying the most accurate NCC.
...
PMID:Use of hyaluronidase in the comparison between manual and automated hematology analysis with the ADVIA 120 to improve analysis of feline body cavity effusions. 2806 34