Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:3.2.1.31 (
beta-glucuronidase
)
7,680
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A method to quantify metabolites of 17beta-nandrolone (17betaN) in boar and horse urine has been optimized and validated. Metabolites excreted in free form were extracted at pH 9.5 with tert-butylmethylether. The aqueous phases were applied to Sep Pak
C18
cartridges and conjugated steroids were eluted with methanol. After evaporation to dryness, either enzymatic hydrolysis with
beta-glucuronidase
from Escherichia coli or solvolysis with a mixture of ethylacetate:methanol:concentrated sulphuric acid were applied to the extract. Deconjugated steroids were then extracted at alkaline pH with tert-butylmethylether. The dried organic extracts were derivatized with MSTFA:NH4I:2-mercaptoethanol to obtain the TMS derivatives, and were subjected to analysis by gas chromatography mass spectrometry (GC/MS). The procedure was validated in boar and horse urine for the following metabolites: norandrosterone, noretiocholanolone, norepiandrosterone, 5beta-estran-3alpha, 17beta-diol, 5alpha-estran-3beta, 17beta-diol, 5alpha-estran-3beta, 17alpha-diol, 17alpha-nandrolone, 17betaN, 5(10)-estrene-3alpha, 17alpha-diol, 17alpha-estradiol and 17beta-estradiol in the different metabolic fractions. Extraction recoveries were higher than 90% for all analytes in the free fraction, and better than 80% in the glucuronide and sulphate fractions, except for 17alpha-estradiol in the glucuronide fraction (74%), and 5alpha-estran-3beta, 17alpha-diol and 17betaN in the sulphate fraction (close to 70%). Limits of quantitation ranged from 0.05 to 2.1 ng mL(-1) in the free fraction, from 0.3 to 1.7 ng mL(-1) in the glucuronide fraction, and from 0.2 to 2.6 ng mL(-1) in the sulphate fraction. Intra- and inter-assay values for precision, measured as relative standard deviation, and accuracy, measured as relative standard error, were below 15% for most of the analytes and below 25%, for the rest of analytes. The method was applied to the analysis of urine samples collected after administration of 17betaN laureate to boars and horses, and its suitability for the quantitation of the metabolites in the three fractions has been demonstrated.
...
PMID:Quantitation of 17beta-nandrolone metabolites in boar and horse urine by gas chromatography-mass spectrometry. 1738 11
A novel method was developed for the simultaneous determination of beta2-agonist residues such as terbutaline, salbutamol, and clenbuterol by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection. The procedure was based on the enhancement effect of beta2-agonists on the CL reaction between luminol and the complex of trivalent copper and periodate ([Cu(HIO6)2]5-), which was on-line electrogenerated by constant current electrolysis. The HPLC separation used a Nucleosil RP-
C18
column (250 mm x 4.6 mm i.d., 5 microm; pore size, 100 A) with a mobile phase consisting of 90% acetonitrile and 10% aqueous ammonium acetate (20 mmol L-1, pH 4.0) at a flow rate of 1.0 mL min-1. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Liver samples were hydrolyzed with
beta-glucuronidase
followed by a solid-phase extraction procedure using Waters OasisMCX cartridges. Under optimum conditions, the limits of detection at a signal-to-noise ratio of 3 ranged from 0.007 to 0.01 ng g-1 and the limits of quantification at a signal-to-noise ratio of 10 ranged from 0.023 to 0.033 ng g-1 for three beta2-agonists. The relative standard deviations (RSDs) of intra- and interday precision were below 4.5%. The average recoveries for beta2-agonists (spiked at the levels of 0.05-5.0 ng g-1) in pig liver ranged from 84 to 110%, and the RSDs of the quantitative results were from 1.6 to 7.2%. The proposed method was successfully applied to the determination of beta2-agonist residues in pig liver samples.
...
PMID:Development of an analytical method for the determination of beta2-agonist residues in animal tissues by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5- -luminol chemiluminescence detection. 1753 25
A gas chromatography/mass spectrometry (GC/MS) method for the simultaneous quantitation of ten estrogen metabolites in human urine was optimized. The method consists of initial enzymatic hydrolysis of the estrogen conjugates using
beta-glucuronidase
followed by solid-phase extraction (SPE) on Sep-pak
C18
columns and further sample purification by ion-exchange chromatography on QAE-Sephadex cartridges in the acetate form. QAE-Sephadex cartridges in the borate form were used to separate estrogens into two fractions: one fraction containing estrogens lacking vicinal cis-hydroxyls (Fr 1) and another containing estrogens possessing vicinal cis-hydroxyls (catecholestrogens; Fr 2). Finally, following O-trimethylsilyl ether derivatization, the estrogens were analyzed by GC/MS in the selected ion monitoring mode. Estrogens were quantitated using deuterated internal standards, which were added to the samples at the initiation of the work-up procedures. After addition to estrogen-low male human samples the standards showed good chromatographic linear response and reproducibility. A reduction in the number of steps and improvements in the robustness of the work-up procedures were achieved. The modified method described is less complex, amenable to use with commercially available SPE columns and fulfils all the reliability criteria, resulting in highly specific and accurate results.
...
PMID:Optimization of an isotope dilution gas chromatography/mass spectrometry method for the detection of endogenous estrogen metabolites in urine samples. 1756 95
A method was developed for the determination of endogenous steroids in urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with methyltestosterone as internal standard. After enzymatic hydrolysis by
beta-glucuronidase
and liquid-liquid extraction, the urine sample was chromatographed on a Cosmosil
C18
column with a mixture of methanol and ammonium acetate-formic acid (68:32, v/v) as mobile phase, then detected using MS/MS system with electrospray ionization (ESI) in multi-reaction monitoring (MRM) mode. The detection limits ranged from 0.01 ng/mL to 10 ng/mL. The recoveries ranged from 96.7% to 106.5%, and the intra- and inter-day precisions (measured as relative standard deviations) were less than 7% and 11%, respectively. With simple and fast sample preparation, the method was sensitive and specific for simultaneous determination of these 5 kinds of endogenous steroids in urine. The method has been successfully applied in pharmacokinetic study and is thus a potential alternative for gas chromatography-mass spectrometry (GC-MS) based procedures in routine analysis of endogenous steroids such as DHEA in human urine.
...
PMID:[Determination of endogenous steroids in urine by liquid chromatography-tandem mass spectromretry]. 1843 17
A high performance liquid chromatography-electrospray ionization mass spectrometry (LC-ESI/MS) was developed to screen and determine trenbolone, tetrahydrogestrinone and gestrinone in human urine. The urine sample was enzymatically hydrolyzed with
beta-glucuronidase
, then extracted with methyl tert-butyl ether. Chromatographic separation was performed on a Zorbax SB-
C18
column (150 mm x 2.1 mm, 5 microm) with ammonium formate buffer (pH 3.5) and acetonitrile as mobile phase. Using positive electrospray ionization mode, the effect of different parameters from electrospray chamber was investigated. The limits of detection based on signal noise ratio of 3 were between 1 and 5 ng. The method can be applied in screening and confirmation of the anabolic steroids in doping control.
...
PMID:[Determination of three anabolic steroids by liquid chromatography-mass spectrometry]. 1895 43
Since corticosteroid metabolism may be affected by disease states, the accurate and precise measurement of endogenous corticosteroids in urine is necessary to understand their biochemical roles. An efficient quantitative profiling of 21 endogenous corticosteroids in urine has been validated by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After enzymatic hydrolysis with
beta-glucuronidase
, samples were purified using a solid-phase extraction cartridge and then separated through a sub-2 microm particle
C18
column (2.1 mm x 50 mm, 1.9 microm) and quantified within 12.1 min using a triple quadrupole MS with electrospray ionization in positive ion mode. All corticosteroids resulted in the base-line separation, which is even achieved for stereo-isomers, such as alpha-/beta-cortol, alpha-/beta-cortolone, and allo-tetrahydrocortisol/tetrahydrocortisol. Overall recoveries ranged from 85% to 106% with limit of quantification ranged from 0.5 to 2.0 ng mL(-1) for the corticosteroids examined. The precision (% CV) and accuracy (% bias) of the assay were 1.7-7.8% and 95.1-105.4%, respectively, in 0.5-200 ng mL(-1) calibration ranges (r(2)>0.9903), for quality-control samples containing 21 endogenous corticosteroids at three different urinary concentrations. Clinical application included quantitative analysis from patients with both prostate cancer and benign prostatic hyperplasia with altered cortisol concentrations. The described LC-MS/MS method eliminates interference from other urine components, has excellent chromatographic resolution achieved by a small particle LC column with a sufficient sensitivity to allow the profiling of both gluco- and mineralo-corticosteroids at a time.
...
PMID:Quantitative metabolic profiling of 21 endogenous corticosteroids in urine by liquid chromatography-triple quadrupole-mass spectrometry. 1910 Aug 88
Taxifolin has been widely used in the treatment of cerebral infarction and sequelae, cerebral thrombus, coronary heart disease and angina pectoris. A reliable sensitive reversed-phase high-performance liquid chromatography (RP-HPLC) method with UV detection for the pharmacokinetic study of taxifolin in rabbit plasma after enzymatic hydrolysis was developed and validated for the first time. Taxifolin, with biochanin A as the internal standard, was extracted from plasma samples by liquid/liquid extraction after hydrolysis with
beta-glucuronidase
and sulfatase. Chromatographic separation was conducted on a Luna
C18
column (4.6 mm x 150 mm, 5 microm particle size) and pre-column (2.0 mm, the same sorbent). Two-step linear gradient elution with acetonitrile and 0.03% water solution of trifluoroacetic acid as mobile phase at a flow rate of 1.0 ml/min was used. The UV detector is set at 290 nm. The elution time for taxifolin and biochanin A was approximately 7.9 and 18.3 min, respectively. The calibration curve of taxifolin was linear (r > 0.9997) over the range of 0.03-5.0 microg/ml in rabbit plasma. The limit of detection (LOD) and limit of quantification (LOQ) for taxifolin were 0.03 and 0.11 microg/ml, respectively. The present method was successfully applied for the estimation of the pharmacokinetic parameters of taxifolin following intravenous and oral administration of lipid solution to rabbits. The absolute bioavailability of taxifolin after oral administration of lipid solution was 36%.
...
PMID:Determination and pharmacokinetic study of taxifolin in rabbit plasma by high-performance liquid chromatography. 1911 Apr 6
A sensitive analytical method has been developed and validated for simultaneous determination of 16 glucocorticoid (fluorometholone, flumethasone, triamcinolone, aldosterone, clobetasol propionate, methylprednisolone, fluocinolone acetonide, hydrocortisone, prednisone, dexamethasone, beclomethasone, prednisolone, budesonide, triamcinolone acetonide, fludrocortisone acetate, and cortisone) residues in pig tissues (muscle, liver, and kidney). These biosamples were hydrolyzed with
beta-glucuronidase
/arylsulfatase enzyme and passed through a Supelclean ENVI-Carb graphitized carbon black solid-phase extraction cartridge, followed by further purification using aminopropyl cartridges. Analytes were separated on an ultra-performance liquid chromatography BEH
C18
column followed by tandem mass spectrometry (MS) with an electrospray ion source. The MS data acquisition was performed in the negative multireaction monitoring mode by a time-scheduled multireaction monitoring program. The assay for the 16 glucocorticoids were linear over the range of 1-250 microg/L for pork, liver, and kidney, with correlation coefficient >0.99. Estimated detection limits for the target analytes ranged from 0.03 to 0.30 microg/kg, and limits of quantitation ranged from 0.10 to 1.00 microg/kg. Recoveries of the glucocorticoids (spiked at levels of 0.4 and 2.0 microg/kg) ranged from 81.0 to 112.3%, with relative standard deviations between 2.6 and 16.6%.
...
PMID:Validation of a solid-phase extraction and ultra-performance liquid chromatographic tandem mass spectrometric method for the detection of 16 glucocorticoids in pig tissues. 1948 21
Suberin composition of various plants including Arabidopsis (Arabidopsis thaliana) has shown the presence of very long chain fatty acid derivatives C20 in addition to the C16 and
C18
series. Phylogenetic studies and plant genome mining have led to the identification of putative aliphatic hydroxylases belonging to the CYP86B subfamily of cytochrome P450 monooxygenases. In Arabidopsis, this subfamily is represented by CYP86B1 and CYP86B2, which share about 45% identity with CYP86A1, a fatty acid omega-hydroxylase implicated in root suberin monomer synthesis. Here, we show that CYP86B1 is located to the endoplasmic reticulum and is highly expressed in roots. Indeed, CYP86B1 promoter-driven
beta-glucuronidase
expression indicated strong reporter activities at known sites of suberin production such as the endodermis. These observations, together with the fact that proteins of the CYP86B type are widespread among plant species, suggested a role of CYP86B1 in suberin biogenesis. To investigate the involvement of CYP86B1 in suberin biogenesis, we characterized an allelic series of cyp86B1 mutants of which two strong alleles were knockouts and two weak ones were RNA interference-silenced lines. These root aliphatic plant hydroxylase lines had a root and a seed coat aliphatic polyester composition in which C22- and C24-hydroxyacids and alpha,omega-dicarboxylic acids were strongly reduced. However, these changes did not affect seed coat permeability and ion content in leaves. The presumed precursors, C22 and C24 fatty acids, accumulated in the suberin polyester. These results demonstrate that CYP86B1 is a very long chain fatty acid hydroxylase specifically involved in polyester monomer biosynthesis during the course of plant development.
...
PMID:CYP86B1 is required for very long chain omega-hydroxyacid and alpha, omega -dicarboxylic acid synthesis in root and seed suberin polyester. 1952 21
Suberin is a protective hydrophobic barrier consisting of phenolics, glycerol, and a variety of fatty acid derivatives, including
C18
:0-C22:0 primary fatty alcohols. An eight-member gene family encoding alcohol-forming fatty acyl-coenzyme A reductases (FARs) has been identified in Arabidopsis (Arabidopsis thaliana). Promoter-driven expression of the
beta-glucuronidase
reporter gene indicated that three of these genes, FAR1(At5g22500), FAR4(At3g44540), and FAR5(At3g44550), are expressed in root endodermal cells. The three genes were transcriptionally induced by wounding and salt stress. These patterns of gene expression coincide with known sites of suberin deposition. We then characterized a set of mutants with T-DNA insertions in FAR1, FAR4, or FAR5 and found that the suberin compositions of roots and seed coats were modified in each far mutant. Specifically,
C18
:0-OH was reduced in far5-1, C20:0-OH was reduced in far4-1, and C22:0-OH was reduced in far1-1. We also analyzed the composition of polymer-bound lipids of leaves before and after wounding and found that the basal levels of
C18
:0-C22:0 primary alcohols in wild-type leaves were increased by wounding. In contrast,
C18
:0-OH and C22:0-OH were not increased by wounding in far5-1 and far1-1 mutants, respectively. Heterologous expression of FAR1, FAR4, and FAR5 in yeast confirmed that they are indeed active alcohol-forming FARs with distinct, but overlapping, chain length specificities ranging from
C18
:0 to C24:0. Altogether, these results indicate that Arabidopsis FAR1, FAR4, and FAR5 generate the fatty alcohols found in root, seed coat, and wound-induced leaf tissue.
...
PMID:Three Arabidopsis fatty acyl-coenzyme A reductases, FAR1, FAR4, and FAR5, generate primary fatty alcohols associated with suberin deposition. 2057 Nov 14
<< Previous
1
2
3
4
5
6