Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.2.1.31 (beta-glucuronidase)
7,680 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A quantitative method was developed for the simultaneous analysis of morphine, codeine, hydromorphone, hydrocodone, and oxycodone in urine by gas chromatography/mass spectrometry. Samples were hydrolyzed with beta-glucuronidase and then extracted by solid phase extraction on Bond Elute Certify cartridges at pH 6.8. Nalorphine was used as the internal standard. The opiates were analyzed by full-scan electron impact GC/MS after derivatization with acetic anhydride-pyridine. The standard curves for all five drugs were linear between 50 and 1000 ng/mL, with correlation coefficients exceeding 0.99. Coefficients of variation were less than 7%. The method was applied to the analysis of postmortem urines positive by EMIT opiate assay, and the effect of the hydrolysis procedure on recovery of each drug was measured. The results indicate that the hydrolysis procedure is effective in increasing the recovery of all five drugs from urine. The described method enables the laboratory to identify the five opiates most commonly encountered in forensic and clinical laboratories. Its sensitivity for all five drugs is well below GC/MS cutoffs for codeine and morphine employed in NIDA laboratories, and it provides for conclusive full-scan drug identification.
...
PMID:A solid phase extraction technique for the isolation and identification of opiates in urine. 128 36

A procedure for the simultaneous confirmation of codeine, morphine, 6-acetylmorphine, hydrocodone, hydromorphone, oxycodone, and oxymorphone in urine specimens by gas chromatography-mass spectrometry (GC-MS) is described. After the addition of nalorphine and naltrexone as the two internal standards, the urine is hydrolyzed overnight with beta-glucuronidase from E. coli. The urine is adjusted to pH 9 and extracted with 8% trifluoroethanol in methylene dichloride. After evaporating the organic, the residue is sequentially derivatized with 2% methoxyamine in pyridine, then with propionic anhydride. The ketone groups on hydrocodone, hydromorphone, oxycodone, oxymorphone, and naltrexone are converted to their respective methoximes. Available hydroxyl groups on the O3 and O6 positions are converted to propionic esters. After a brief purification step, the extracts are analyzed by GC-MS using full scan electron impact ionization. Nalorphine is used as the internal standard for codeine, morphine, and 6-acetylmorphine; naltrexone is used as the internal standard for the 6-keto-opioids. The method is linear to 2000 ng/mL for the 6-keto-opioids and to 5000 ng/mL for the others. The limit of quantitation is 25 ng/mL in hydrolyzed urine. Day-to-day precision at 300 and 1500 ng/mL ranged between 6 and 10.9%. The coefficients of variation for 6-acetylmorphine were 12% at both 30 and 150 ng/mL. A list of 38 other basic drugs or metabolites detected by this method is tabulated.
...
PMID:GC-MS confirmation of codeine, morphine, 6-acetylmorphine, hydrocodone, hydromorphone, oxycodone, and oxymorphone in urine. 1036 27