Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.2.1.23 (beta-galactosidase)
14,648 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

An integrated amperometric biosensor for the determination of lactose is reported. The bioelectrode design is based on the use of a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode on which the enzymes beta-galactosidase (beta-Gal), glucose oxidase (GOD), peroxidase (HRP) and the mediator tetrathiafulvalene (TTF) are coimmobilized by a dialysis membrane. beta-Gal catalyzes the hydrolysis of lactose, and the produced glucose is catalytically oxidized to gluconic acid and H(2)O(2), which is reduced in the presence of HRP. This enzyme reaction is mediated by TTF, and the reduction of TTF(+) at 0.00 V (vs Ag/AgCl) gives rise to an amperometric signal proportional to the lactose concentration. The biosensor exhibits a good repeatability of the measurement carried out with the same biosensor, a good reproducibility of the responses obtained with different biosensors and a useful lifetime of 28 days. A linear calibration plot was obtained for lactose over the 1.5 x 10(-6) to 1.2 x 10(-4) M concentration range, with a limit of detection of 4.6 x 10(-7) M. The effect of potential interferents (sucrose, lactulose, fructose, arabinose, maltose, galactose, glucose and uric and ascorbic acids) on the biosensor response was evaluated. Furthermore, the bioelectrode exhibits a suitable performance in flow-injection systems in connection with amperometric detection. The developed biosensor was applied to the determination of lactose in milk and other foodstuffs (chocolate, butter, margarine, yogurt, cheese and mayonnaise), and the results obtained were validated by comparison with those provided by using a commercial enzyme test kit.
...
PMID:An integrated amperometric biosensor for the determination of lactose in milk and dairy products. 2050 93

A novel enzyme reactor with co-immobilization of beta-galactosidase and glucose oxidase in calcium alginate fiber (CAF) and amine modified nanosized mesoporous silica (AMNMS) was prepared which incorporate the adsorption and catalysis of AMNMS with the cage effect of the polymer to increase catalytic activity and stability of immobilized enzyme. The enzyme reactor was applied to prepare a chemiluminescence (CL) flow-through biosensor for determination of lactose combined with a novel luminol-diperiodatonickelate (DPN) CL system we reported. It shows that the CL flow-through biosensor possesses long lifetime, high stability, high catalytic activity and sensitivity. The relative CL intensity was linear with the lactose concentration in the range of 8 x 10(-8) - 4 x 10(-6) g mL(-1) with the detection limit of 2.7 x 10(-8) g mL(-1) (3sigma). It has been successfully applied to the determination of lactose in milk.
...
PMID:Application of a novel co-enzyme reactor in chemiluminescence flow-through biosensor for determination of lactose. 2068 73


<< Previous 1 2 3 4