Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.1.4.1 (phosphodiesterase)
18,767 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

1. cAMP Phosphodiesterase activity and kinetic parameters (Km and Vmax) were measured in subcutaneous and perirenal adipocyte plasma membranes from Large White male and castrated pigs. The animals were fed a control low fat diet or a sunflower diet enriched with linoleic acid (C18:2 n-6). 2. Phosphodiesterase activity, low Km and Vmax were lowered by castration. 3. In animals fed the sunflower diet, phosphodiesterase activity decreased without affecting either Km or Vmax. 4. Phosphodiesterase activity was higher in perirenal sites than in subcutaneous ones, particularly in male pigs. This may be explained by a lower Km or a higher cAMP phosphodiesterase affinity to cAMP in perirenal sites. 5. Theophylline was a potent inhibitor of phosphodiesterase activity principally in perirenal sites. 6. The intermediate role of cAMP phosphodiesterase in adenylate cyclase activity and lipolytic processes is discussed.
...
PMID:Effects of castration, dietary fat and adipose tissue sites on adipocyte plasma-membranes cyclic AMP phosphodiesterase activity in the pig. 166 23

An assay for thymidine substitution by iododeoxyuridine (IdUrd) using reversed-phase high-performance liquid chromatography (HPLC) has been developed. Three principal steps in this procedure are: extraction of DNA from cell or tissues, hydrolysis of DNA into deoxynucleosides and separation using HPLC. Approximately 1 microgram of DNA was recovered from 10(5) cells by phenol extraction, and subjected to hydrolysis into deoxynucleosides which required a three-stage DNA digestion using enzymes DNAse I. phosphodiesterase I and alkaline phosphatase. The deoxynucleosides were separated on the Microsorb C18 column with isocratic elution; 90-100% of the DNA was recovered as deoxynucleosides on the column. The method was used to determine quantitatively the percent IdUrd substitution of thymidine in Chinese hamster lung cells in vitro and BA1112 rhabdomyosarcoma in WAG/Rij rats perfused with IdUrd. It was possible to determine the thymidine substitution by IdUrd as small as 1% using a few micrograms of DNA. The close correspondence between the percent substitutions determined by HPLC and those determined by radioactive assay using [125I]-labelled IdUrd, confirmed the accuracy of our HPLC method. The HPLC analysis is especially suitable for the determination of percent IdUrd substitution of thymidine in tissue biopsies from animals used in in vivo experiments or humans undergoing radiation treatment.
...
PMID:A method for determination of iododeoxyuridine substitution of thymidine using reversed-phase high-performance liquid chromatography. 200 16

One of the major determinants of the short-term effects of many cardioactive drugs is the concentration of the drug specifically within the myocardium. However, no information regarding the disposition of the phosphodiesterase inhibitor milrinone in the heart is available. We therefore determined the time course of short-term myocardial milrinone uptake from paired transcoronary sampling and simultaneous coronary sinus blood flow after a 1-mg intravenous bolus in patients undergoing diagnostic cardiac catheterization. In accordance with this intention, a sensitive, reproducible method for the determination of milrinone in human whole-blood samples was developed. The reverse-phase high-performance liquid chromatographic method described used a C18 column with UV-absorbance detection at 326 nm, with a limit of detection of 0.6 ng/ml, and was highly reproducible. The short-term hemodynamic and electrophysiologic effects of the drug also were determined. Significant increases in spontaneous heart rate and LV+dP/dtmax (at constant heart rate) were observed, accompanied by reductions in mean arterial pressure, systemic vascular resistance, and PR interval, without significant changes in atrioventricular nodal or ventricular effective refractory periods. Peak content (1.89 +/- 0.30% of injected dose) was rapidly attained, 0.56 +/- 0.06 min after milrinone injection. Time of peak effects was significantly delayed (7-10 min after injection) relative to time of peak myocardial milrinone content. Residual myocardial milrinone content was 69.1 +/- 5.7% of maximum 12.5 min after injection. It is concluded that both myocardial uptake and the onset of positive inotropic effects after intravenous injection of milrinone were very rapid. However, there was significant hysteresis between peak myocardial content and subsequent hemodynamic effects.
...
PMID:Relationship between myocardial milrinone content and its acute hemodynamic and electrophysiologic effects. 964 73

The metabolism of N-(3,5-dichloropyrid-4-yl)-3-cyclopentyloxy-4-methoxybenzamide (RP73401), a phosphodiesterase IV (PDE IV) inhibitor is extensive (unpublished); however, until recently, studies for this compound did not report 4-amino-3,5-dichloropyridine (ADCP) as a metabolite either in vitro or in vivo. This prompted a reinvestigation into the metabolism of RP73401 in rats and mice using mass spectrometry. The results of the reinvestigation confirmed that 4-amino-3,5-dichloropyridine was formed via the metabolism of RP73401 both in vitro and in vivo. In order to further investigate RP73401 hydrolysis in vivo, a liquid chromatography/mass spectrometry assay was developed and validated for the simultaneous determination of RP73401 and ADCP in rat and mouse plasma. The method used Waters Oasis HLB brand solid phase extraction cartridges to isolate the analytes (RP73401 and ADCP) and internal standard from the plasma. HPLC chromatographic separation was achieved using a Zorbax SB C18 HPLC column and detection was accomplished using positive ion atmospheric pressure chemical ionization tandem mass spectroscopy in multiple reaction monitoring (MRM) mode. The assay was developed and validated over the range of 0.5-100 ng ml(-1) for RP73401 and 5-500 ng ml(-1) for ADCP using 0.050 ml of plasma. The assay proved to be sensitive, accurate, precise and specific for RP73401 and ADCP. Intraday and interday quality control results routinely showed accuracy and precision to be within +/- 20%. This LC/MS/MS method was subsequently employed to investigate the hydrolysis of RP73401 in the rat and mouse, and determine the effects of tri-o-tolyl phosphate (TOTP, a carboxylesterase inhibitor) preadministration on the hydrolysis reaction in the rat.
...
PMID:Quantitation of N-(3,5-dichloropyrid-4-yl)-3-cyclopentyloxy-4-methoxybenzamide and 4-amino-3,5-dichloropyridine in rat and mouse plasma by LC/MS/MS. 1081 28

While studying the calmodulin activity in post-climacteric apples, a heat stable, dialyzable component that inhibited calmodulin-promoted phosphodiesterase activity was detected. The compound(s) that inhibited calmodulin activity did not bind to Dowex-50, H+ or Dowex-2, Cl- and was exclusively present in the neutral fraction. The inhibitors irreversibly bound to polyvinylpolypyrrolidone indicating their phenolic nature. Fractionation of the neutral fraction on a C18-microbondapak column and analysis for the inhibition of calmodulin-promoted phosphodiesterase activity showed significant inhibitory activity associated with fractions eluted 5 min, 15 min and 18 min after injection. Perdeuteriomethylation and combined gas chromatographic-mass spectrometric analysis of the inhibitors showed them to be flavonoids. (+)-Catechin was identified in the fraction eluted 5 min after injection that also showed maximum inhibition. Other flavonoids such as epicatechin, quercetin and naringenin also inhibited calmodulin-promoted phosphodiesterase activity. Among the phenolic compounds commonly encountered in plant tissue only caffeic acid inhibited calmodulin-promoted phosphodiesterase activity. Inhibition by catechin and caffeic acid could be reversed by increasing the calmodulin concentration in the assay mixture. Both catechin and caffeic acid inhibited Ca- and calmodulin-promoted phosphorylation of soluble proteins from corn coleoptiles. The physiological properties of flavonoids are discussed in light of this evidence.
...
PMID:Identification of naturally occurring calmodulin inhibitors in plants and their effects on calcium- and calmodulin-promoted protein phosphorylation. 1154 Aug 53

A sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet absorption detection (292 nm) was developed and validated for the determination of the new phosphodiesterase V inhibitor, DA-8159 (DA), in human plasma and urine. A single step liquid-liquid extraction procedure using ethyl ether was performed to recover DA and the internal standard (sildenafil citrate) from 1.0 ml of biological matrices combined with 200 microl of 0.1M sodium carbonate buffer. A Capcell Pak C18 UG120 column (150 mm x 4.6 mm I.D., 5 microm) was used as a stationary phase and the mobile phase consisted of 30% acetonitrile and 70% 20mM potassium phosphate buffer (pH 4.5) at a flow rate of 1.0 ml/min. The lower limit for quantification was 5 ng/ml for plasma and 10 ng/ml for urine samples. Within- and between-run accuracy and precision were < or =15 and < or =10%, respectively, in both plasma and urine samples. The recovery of DA from human plasma and urine was greater than 70%. Separate stability studies showed that DA is stable under the conditions of analysis. This validated assay was used for the pharmacokinetic analysis of DA during a phase I, rising dose study.
...
PMID:Sensitive liquid chromatography assay with ultraviolet detection for a new phosphodiesterase V inhibitor, DA-8159, in human plasma and urine. 1452 22

The epithelial sodium channel is found in apical membranes of a variety of native epithelial tissues, where it regulates sodium and fluid balance. In vivo, a number of hormones and other endogenous factors, including polyunsaturated fatty acids (PUFAs), regulate these channels. We tested the effects of essential n-3 and n-6 PUFAs on amiloride-sensitive sodium transport in A6 epithelial cells. Eicosapentaenoic acid [EPA; C20:5(n-3)] transiently stimulated amiloride-sensitive open-circuit current (I(Na)) from 4.0 +/- 0.3 to 7.7 +/- 0.3 microA/cm2 within 30 min (P < 0.001). No activation was seen in the presence of 10 microM amiloride. In cell-attached but not in cell-excised patches, EPA acutely increased the open probability of sodium channels from 0.45 +/- 0.08 to 0.63 +/- 0.10 (P = 0.02, paired t-test). n-6 PUFAs, including linoleic acid (C18:2), eicosatetraynoic acid (C20:4), and docosapentanoic acid (C22:5) had no effect, whereas n-3 docosahexanoic acid (C22:6) activated amiloride-sensitive I(Na) in a manner similar to EPA. Activation of I(Na) by EPA was prevented by H-89, a PKA inhibitor. Similarly, PKA activity was stimulated by EPA. Nonspecific stimulation of phosphodiesterase activity by CoCl2 completely prevented the effect of EPA on sodium transport. We conclude that n-3 PUFAs activate epithelial sodium channels downstream of cAMP in a cAMP-dependent pathway also involving PKA.
...
PMID:Modulation of epithelial Na+ channel activity by long-chain n-3 fatty acids. 1519 29

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantitation of tadalafil (I) in human plasma, a new selective, reversible phosphodiesterase 5 inhibitor. The analyte and internal standard (sildenafil, II) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (10/90, v/v, pH adjusted to 3.0 with formic acid). The protonate of analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 390.4 --> 268.0 and m/z 475.5 --> 58.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-1000 ng/mL for tadalafil in human plasma. The lower limit of quantitation was 10 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.
...
PMID:Quantitation of tadalafil in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionization. 1531 72

Tadalafil is a potent reversible phosphodiesterase-5 inhibitor used for the treatment of erectile dysfunction. This study describes a simple and sensitive high-performance liquid chromatographic (HPLC) method for the determination of tadalafil in 50 microl of rat plasma. Tadalafil and the internal standard lamotrigine were extracted with 0.5 ml of tert-butyl methyl ether, after the samples alkalinized with 20 microl of sodium hydroxide solution (1N). Chromatographic separation was achieved on a C18 column with the mobile phase of acetonitrile-water containing 20 mM phosphate buffer (pH 7) (35/65, v/v), at a flow rate of 1 ml/min. The eluant was detected at 290 nm. The retention time was about 4.5 min for lamotrigine and 15 min for tadalafil. No endogenous substances were found to interfere. Calibration curves were linear from 10 to 2000 ng/ml. The recovery of tadalafil from plasma was greater than 77%. The limit of quantitation was 10 ng/ml. The intra- and inter-day imprecision (expressed as coefficient of variation, C.V.) did not exceed 10.7%, and the accuracy was within 5.9% deviation of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring tadalafil concentration.
...
PMID:Determination of tadalafil in small volumes of plasma by high-performance liquid chromatography with UV detection. 1599 35

MSP001 is a newly synthesized piperidine analog of the lead antihypertensive compound MS23 that dually targets cAMP-specific type 4 phosphodiesterase and L-type calcium channels. We validated an analytical protocol for MSP001 in rat plasma using high performance liquid chromatographic method. A C18 column and a phosphate/acetonitrile buffer were used to perform the chromatographic separation. UV detection was carried out at 307 nm, a wavelength at which an absorption peak was detected for this group of compounds. The calibration curve for MSP001 was linear in the range from 25 to 10,000 ng/ml. The limit of quantification (LOQ) was 25 ng/ml. The results demonstrate that this method has high linearity (R=0.99995), compound specificity, and acceptable precision/accuracy. The protocol is suitable for in vivo pharmacokinetic studies on the compound.
...
PMID:High performance liquid chromatographic analysis of MS23 piperidine analog MSP001 in rat plasma. 1681 62


1 2 3 Next >>