Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.1.30.2 (endonuclease)
18,621 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Factor V Leiden and prothrombin G20210A are clinically relevant genetic risk factors for venous thrombosis. Analysis for both mutations is increasingly being performed on patients exhibiting hypercoagulability. The goal of the current study was to evaluate the performance of primer-engineered multiplex polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) for the simultaneous detection of factor V Leiden and prothrombin G20210A. Primer-engineered multiplex PCR-RFLP methods for the detection of factor V Leiden and prothrombin G20210A from the medical literature were reviewed. A modified method was optimized in which both mutations generate HindIII RFLPs and the prothrombin amplicon contains an invariant HindIII recognition site to assess the completeness of endonuclease digestion. Digested amplification products were analyzed by agarose gel electrophoresis in a single gel lane and visualized by ethidium bromide. Primer-engineered multiplex PCR-RFLP was used to analyze 205 human genomic DNA samples whose factor V Leiden genotypes had been previously determined by MnlI PCR-RFLP. Complete concordance for factor V Leiden genotypes was observed between the two methods in the 205-sample cohort comprising 139 wild-type, 62 heterozygous mutant, and four homozygous mutant individuals. For prothrombin G20210A, primer-engineered multiplex PCR-RFLP identified 196 wild-type and nine heterozygous mutant individuals in the 205-sample cohort. To independently verify prothrombin genotypes, the nine heterozygous mutants and an additional 11 wild-type patient samples (representing 10% of patient samples) were subjected to DNA sequencing. Complete concordance was observed between DNA sequencing and primer-engineered multiplex PCR-RFLP results. In further validation, 123 of the DNA samples consisting of four heterozygous mutant and 119 wild type individuals were genotyped with the Invader Assay for Factor II (prothrombin G20210A). Results showed 100% concordance between the Invader Assay and primer-engineered multiplex PCR-RFLP. A primer-engineered multiplex PCR-RFLP based on single restriction endonuclease digestion has been evaluated and shown to simultaneously and accurately detect factor V Leiden and prothrombin G20210A mutations. The method is robust and readily adaptable to the clinical molecular diagnostic laboratory.
...
PMID:Analytical evaluation of primer engineered multiplex polymerase chain reaction-restriction fragment length polymorphism for detection of factor V Leiden and prothrombin G20210A. 1122 20

Simple, low-cost and accurate genotyping methods for single nucleotide polymorphisms (SNPs) are in high demand in the post-genome-sequencing era. We present a graphical tool called SNPicker, implemented in Java, which significantly facilitates the design of mutagenic endonuclease restriction assays. SNPicker uses the online NEB REBASE to automatically scan for all possible designs of mutagenic primers that can facilitate the picking of mismatched PCR primers to artificially introduce or abolish a restriction site at the target SNP site. We successfully applied SNPicker in designing endonuclease restriction assays for 14 SNPs for the MTHFR gene, the Coagulation Factor II gene and the Coagulation Factor V gene. The SNP assays designed using SNPicker were cross-validated using the MassARRAY technology.
...
PMID:SNPicker: a graphical tool for primer picking in designing mutagenic endonuclease restriction assays. 1520 Nov 86