Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:3.1.1.8 (
cholinesterase
)
12,691
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
An automated method using 2,2'-dithiodipyridine (2-
PDS
) as chromophore for determination of whole-blood
cholinesterase
activity was developed. Assay procedures, optimal concentrations of chromophore and substrate, detection limit, precision, backgrounds, and sensitivity of the method were compared with those of an earlier automated method based on the Ellman method and using 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB) as chromophore. The new method has the advantages of automation (resulting in increase throughput rate and decrease in amount of reagents used) and good precision and sensitivity. Sample dilutions also are reduced in the new method because hemoglobin interference is less.
...
PMID:Automated spectrophotometric method using 2,2'-dithiodipyridine acid for determination of cholinesterase in whole blood. 863 43
Effects of seven different blood diluents (distilled water, Triton X-100, saponin, isotonic saline solution, pH 7.5 and 8 phosphate buffers and bovine serum albumin) and two chromophores: 5, 5'-dithiobis 2-nitrobenzoic acid (DTNB) and 2,2'-dithiodipyridine (2-
PDS
) on blood
cholinesterase
determination in four domestic species (cow, sheep, goat and horse) are described and compared. Haemolytic diluents (distilled water, Triton X-100 and saponin) gave the best precision results when fresh blood was assayed. However, Triton X-100 induced lower ChE activity values in horses, and saponin yielded very high backgrounds in all species tested; so distilled water was recommended as diluent for fresh blood
cholinesterase
determination. In frozen samples all diluents (except Triton X-100) gave homogeneous final ChE results and showed good between-run precision. Use of 2-
PDS
as chromophore allowed to do kinetic measurements with approximately 1/3 less haemoglobin interference than when DTNB was employed. This fact allows the use of more concentrated whole blood samples, improving measurements accuracy and decreasing the possible reactivation of inhibited ChE. On the basis of these results, distilled water as diluent and 2-
PDS
as chromophore are recommended for ChE determination in whole blood.
...
PMID:Comparison of different diluents and chromophores for spectrophotometric determination of livestock blood cholinesterase activity. 1060 6