Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:2.7.7.48 (
transcriptase
)
9,479
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A combined bio-analytical assay for abacavir, a reversed
transcriptase
inhibitor, and mycophenolic acid (MPA), based on reversed-phase liquid chromatography and both ultraviolet (UV) absorption and fluorescence detection, is reported. Both analytes are extracted from plasma with
acetonitrile
. After centrifugation, evaporation of the supernatant and reconstitution in water, the sample is injected into the chromatograph. Abacavir is detected using UV detection at 285 nm and MPA spectrofluorometrically at 345 and 430 nm for excitation and emission, respectively. The method has been validated in the 80-2000 ng/ml range for abacavir and in the 10-10,000 ng/ml range for MPA for 200-microl plasma samples. The lower limits of quantification are 80 and 10 ng/ml for abacavir and MPA, respectively. Precisions and accuracies are < or = 8% in the valid concentration ranges of both analytes.
...
PMID:Liquid chromatographic assay for simultaneous determination of abacavir and mycophenolic acid in human plasma using dual spectrophotometric detection. 1120 16
The new non-reversed
transcriptase
inhibitor (NRTI) drugs for treatment of acquired immunodeficiency syndrome (AIDS) are reported. An improvement in the sensitivity and selectivity of high-performance liquid chromatography was obtained by diamond electrode-electrochemical detector and fluorescence detector owing to different structural information. The four anti-retroviral NRTI drugs (abacavir, didanosine, lamivudine and zidovudine) were separated on a CapcellPak C18 UG120 column (250 mm x 4.6 mm I.D., 5 microm) with an
acetonitrile
-25 mM potassium dihydrogenphosphate buffer (pH 8.0; 1:9, v/v) as the mobile phase. We applied dual detection (electrochemical detection and florescence detection) for improving the peak identification and also for improved selectivity, which assisted monitoring by trace-volume samples (e.g., plasma). The electrochemical detector, equipped with a diamond electrode, was set at 2000 mV (applied voltage) and the fluorescence detector was set at excitation wavelength 275 nm and emission wavelength 315 nm. The detection limits of the four NRTIs in spiked plasma were 1-100 ng/ml by electrochemical detection and 5-10 pg/ml by fluorescence detection. The calibration graphs were linear up to 20 microg/ml by electrochemical detection and 10 microg/ml by fluorescence detection. This is the first report of LC analysis of NRTIs by electrochemical detection, also combined with fluorescence detection. The detection limits of didanosine, lamivudine and zidovudine were improved 20-fold by electrochemical detection and 500-fold by fluorescence detection compared to previous reports on UV detection. The selectivity was also improved by dual detection. The proposed method was applied to the preliminary monitoring of NRTIs in plasma.
...
PMID:Improvement of sensitivity and selectivity of high-performance liquid chromatography for anti-retroviral drugs (non-reverse transcriptase inhibitors) by diamond-electrode electrochemical and fluorescence detection. 1923 77