Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:2.7.11.8 (
FAST
)
758
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Irrelevant IgE binding to cellulose discs is known to give false positive results in Phadezym RAST (Pharmacia) for the estimation of allergen-specific IgE in serum. We investigated
FAST
-Plus Test (3M Diagnostic Systems), an enzyme-linked sandwich type
Fluoro
-Allergo-Sorbent Test in which a particular allergen was coated to polystyrene well. Phadezym RAST and CAP RAST (Pharmacia) using cellulose-derivative discs as adsorbent were used as reference methods. Patients' sera which gave negative blank reactions to uncoated filter paper disc in the Phadezym RAST system were assayed for specific IgE to 6 allergens using
FAST
-Plus Test, CAP RAST and Phadezym RAST, and the results of the former two were compared with those of Phadezym RAST using a comparable class system.
FAST
-Plus Test showed variable correlations with Phadezym RAST, the correlation coefficients ranged from 0.41 to 0.97 (r = 0.462 in house dust 1, r = 0.713 in house dust 2, r = 0.412 in Candida albicans, r = 0.952 in Dermatophagoides peteronyssinus, r = 0.969 in Dermatophagoides farinae and r = 0.682 in Japanese cedar), although most of the results were within one class difference. Similar correlations were obtained between CAP RAST and Phadezym RAST. Of 3004 patients' sera tested in the past two years using Phadezym RAST, 132 (96 cases) displayed positive blank reactions to the uncoated filter paper disc. Of the 96 cases, 80 sera were assayed for binding of IgE to the uncoated cellulose-derivative disc in the CAP RAST system. 18 showed positive results up to 7 IU/ml.(ABSTRACT TRUNCATED AT 250 WORDS)
...
PMID:[False positive reaction in measurement of allergen-specific IgE--comparison of 3M IgE FAST-Plus Test using polystyrene well as adsorbent with Phadezym RAST]. 130 29
This reports covers the application to paediatrics of total IgE determination by the means of a new direct, sandwich type, fluorescence enzyme immuno-assay (
Fluoro
-allergo sorbent test:
FAST
IgE). The technical process is adapted for usual determinations, in case of infants and young children, of low normal rates with a good sensitivity, and of high pathological rates. IgE total usual values are established by the
FAST
IgE test from serums of healthy children, aged from one day to 14 years. Seven age groups are to be distinguished.
...
PMID:[Total serum IgE: normal pediatric values using the FAST IgE fluoroimmunoenzymatic technic]. 333 Nov 7
Diagnosis of cartilage damage in early stages of arthritis is vital to impede the progression of disease. In this regard, considerable progress has been made in near-infrared fluorescence (NIRF) optical imaging technique. Arthritis can develop due to various mechanisms but one of the main contributors is the production of matrix metalloproteinases (MMPs), enzymes that can degrade components of the extracellular matrix. Especially, MMP-1 and MMP-13 have main roles in rheumatoid arthritis and osteoarthritis because they enhance collagen degradation in the process of arthritis. We present here a novel NIRF imaging strategy that can be used to determine the activity of MMPs and cartilage damage simultaneously by detection of exposed type II collagen in cartilage tissue. In this study, retro-orbital injection of mixed fluorescent dyes, MMPSense 750
FAST
(MMP750) dye and Alexa
Fluor
680 conjugated monoclonal mouse antibody immune-reactive to type II collagen, was administered in the arthritic mice. Both dyes were detected with different intensity according to degree of joint destruction in the animal. Thus, our dual fluorescence imaging method can be used to detect cartilage damage as well as MMP activity simultaneously in early stage arthritis.
...
PMID:In Vivo Dual Fluorescence Imaging to Detect Joint Destruction. 2718 38