Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:2.7.10.2 (focal adhesion kinase)
44,029 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

This study describes a method for the determination of phosphorus in lyophilized Haemophilus influenzae type b conjugate vaccines by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The concentration of polysaccharide is directly related to the concentration of phosphorus as measured in the laboratory. Phosphorus is present in the polyribosyl-ribitol phosphate (PRP) group of the Haemophilus influenzae type b conjugate vaccine. The repeating unit of PRP is 3-B-D ribose[1-1]ribitol-5-phosphate. Phosphorus in the final container is measured in microg per dose. The amount of PRP is calculated from this and reported in microg per dose. The Haemophilus influenzae type b conjugate vaccine was analyzed for phosphorus content within the range of 1.34 to 2.02 microg phosphorus per ml. The relative difference of phosphorus concentrations determined by the ICP-AES method from the phosphorus concentrations determined by the traditional colorimetric molybdate method ranged from 2.2 to 10.6%. Phosphorus spike recovery for the vaccine ranged from 93 to 99% (1.93+/-0.13 microg P/ml). The phosphorus determination of NIST SRM 3139 phosphorus spectrometric solution differed by 3.0% from the certified phosphorus value (10.00 mg P/ml).
...
PMID:The determination of phosphorus in Haemophilus influenzae type b conjugate vaccines by inductively coupled plasma-atomic emission spectrometry. 1123 58

A speciation technique for arsenic has been developed using an anion-exchange high-performance liquid chromatography/inductively coupled argon plasma mass spectrometer (HPLC/ICP MS). Under optimized conditions, eight arsenic species [arsenocholine, arsenobetaine, dimethylarsinic acid (DMA(V)), dimethylarsinous acid (DMA(III)), monomethylarsonic acid (MMA(V)), monomethylarsonous acid (MMA(III)), arsenite (As(III)), and arsenate (As(V))] can be separated with isocratic elution within 10 min. The detection limit of arsenic compounds was 0.14-0.33 microg/L. To validate the method, Standard Reference Material in freeze-dried urine, SRM-2670, containing both normal and elevated levels of arsenic was analyzed. The method was applied to determine arsenic species in urine samples from three arsenic-affected districts of West Bengal, India. Both DMA(III) and MMA(III) were detected directly (i.e., without any prechemical treatment) for the first time in the urine of some humans exposed to inorganic arsenic through their drinking water. Of 428 subjects, MMA(III) was found in 48% and DMA(III) in 72%. Our results indicate the following. (1) Since MMA(III) and DMA(III) are more toxic than inorganic arsenic, it is essential to re-evaluate the hypothesis that methylation is the detoxification pathway for inorganic arsenic. (2) Since MMA(V) reductase with glutathione (GSH) is responsible for conversion of MMA(V) to MMA(III) in vivo, is DMA(V) reductase with GSH responsible for conversion of DMA(V) to DMA(III) in vivo? (3) Since DMA(III) forms iron-dependent reactive oxygen species (ROS) which causes DNA damage in vivo, DMA(III) may be responsible for arsenic carcinogenesis in human.
...
PMID:Identification of dimethylarsinous and monomethylarsonous acids in human urine of the arsenic-affected areas in West Bengal, India. 1130 25

The direct determination of trace impurities in Al2O3 ceramic basic powders by ICP-MS using electrothermal evaporation (ETV) with slurry sampling has been investigated. To increase interference-free analyte volatilization, the use of the palladium-group modifiers (PGM) IrCl3, Pd(NO3)2, and PdCl2 for the determination of Ca, Fe, Ga, Mg, Mn, Na, Ni, and V in Al2O3 powders was studied. Their role, which in ETV-ICP-MS and ETV-ICP-OES is to stabilize the investigated analyte during the ashing phase, to increase vaporization of the matrix, and to reduce transport losses was investigated. Optimum analysis results were obtained with PdCl2 modifier when 500 ng Pd was used for a sample weight of 100 microg Al2O3 injected into the ETV. Calibration was performed by standard addition with aqueous solutions of the analytes. The RSDs calculated from triplicate analysis ranged form 5 to 10%. Detection limits between 0.07 microg g(-1) (Ga) and 1.1 microg g(-1) (Na) were achieved. The accuracy was proven for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni, and V by analyzing an NIST standard reference Al2O3 material (SRM 699) with a middle grain size of 16.4 microm. The analytical method was used for the analysis of Al2O3 powder (AKP 30, Sumitomo, Japan) with impurities in the low microg g(-1) range and a middle grain size of 1.1 microm. The results obtained for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni, and V were comparable with those obtained by ICP-MS subsequent to conventional decomposition with hydrochloric acid at high pressure.
...
PMID:Investigations on the use of chemical modifiers for the direct determination of trace impurities in Al2O3 ceramic powders by slurry electrothermal evaporation coupled with inductively-coupled plasma mass spectrometry (ETV-ICP-MS). 1149 80

The capability of a second-generation Nu Instruments multiple collector inductively coupled plasma mass spectrometer (MC-ICP-MS) has been evaluated for precise and accurate isotope-ratio determinations of lead. Essentially the mass spectrometer is a double-focusing instrument of Nier-Johnson analyzer geometry equipped with a newly designed variable-dispersion ion optical device, enabling the measured ion beams to be focused into a fixed array of Faraday collectors and an ion-counting assembly. NIST SRM Pb 981, 982, and 983 isotopic standards were used. Addition of thallium to the lead standards and subsequent simultaneous measurement of the thallium and lead isotopes enabled correction for mass discrimination, by use of the exponential correction law and 205Tl/203Tl = 2.3875. Six measurements of SRM Pb-982 furnished the results 206Pb/204Pb = 36.7326(68), 207Pb/204Pb = 17.1543(30), 208Pb/204Pb = 36.7249(69), 207Pb/206Pb = 0.46700(1), and 208Pb/206Pb = 0.99979(2); the NIST-certified values were 36.738(37), 17.159(25), 36.744(50), 0.46707(20), and 1.00016(36), respectively. Direct isotope lead analysis in silicates can be performed without any chemical separation. NIST SRM 610 glass was dissolved and introduced into the MC-ICP-MS by means of a micro concentric nebulizer. The ratios observed were in excellent agreement with previously reported data obtained by TIMS and laser ablation MC-ICP-MS, despite the high Ca/Pb concentration ratio (200/1) and the presence of many other elements at levels comparable with that of lead. Approximately 0.2 microg lead are sufficient for isotope analysis with ratio uncertainties between 240 and 530 ppm.
...
PMID:Isotope-ratio measurements of lead in NIST standard reference materials by multiple-collector inductively coupled plasma mass spectrometry. 1149 96

An extraction method was developed for the determination of toxic elements in contaminated soil samples by inductively coupled plasma atomic emission spectrometry (ICP-AES). The determination of arsenic, cadmium, lead, and silver in ultrasound-assisted extracts of SRM 2710 and SRM 2711 by ICP-AES was carried out with high accuracy and precision (RSD<3.7%). The certified concentrations of the SRMs were obtained for arsenic, cadmium, lead, and silver by using an ultrasound-assisted extraction method with a digestion solution of (1+1)-diluted aqua regia. The determination of copper in SRMs by the ultrasound-assisted extraction method and analysis by ICP-AES failed to obtain the certified concentrations at the 95% level of confidence using (+/-2 s) as confidence limits of the mean. However, the same results were observed with the use of the microwave digestion method and reflux, which is the ISO 11466 standard method. The analysis of the SRMs showed that the ultrasound-assisted extraction method is highly comparable with the other methods used for such purposes. The major advantages of the ultrasound-assisted extraction method compared to the microwave and reflux methods are the high treatment rate (50 samples simultaneously in nine minutes) and low reagent usage, the main benefit of which are the low chloride and nitrate concentrations in the extracts.
...
PMID:Ultrasound-assisted extraction in the determination of arsenic, cadmium, copper, lead, and silver in contaminated soil samples by inductively coupled plasma atomic emission spectrometry. 1201 78

A previously developed microwave heated vapor-phase digestion method for biological samples was modified to enable digestion of difficult to digest organic samples. Organic samples containing ca. 100 mg of organic carbon were digested using volume calibrated quartz inserts inside second generation type medium pressure microwave vessels. As digestion reagents, 98% sulfuric acid, 70% nitric acid and 30% hydrogen peroxide were used. The accuracy of the method was tested with six certified reference materials. Elements Ca, Fe, K, Na, Mg, P and Zn were determined from NIST-SRM 8433 corn bran. Elements Al, Fe, Cd, Cu, and Zn were determined from NRCC DOLT-2 dogfish liver. The element Cd was determined from IRMM-VDA Cd in polyethylene No. 001-004 reference materials. These elements were determined from digested samples by ICP-OES. The results were close or within certified limits. The modified method could digest nearly all the materials tested, including the above mentioned reference materials, 2-nitrobenzoic acid (2-NBA), 4-NBA and copper(II) phthalosyanine-3, 4',4',4'-tetrasulfonic acid tetrasodium salt (CPS). The method could not digest 3-NBA.
...
PMID:Development of a modified medium pressure microwave vapor-phase digestion method for difficult to digest organic samples. 1262 63

Variations in Hg isotope ratios in cinnabar ores obtained from different countries were detected by high precision isotope ratio measurements using multi-collector inductively coupled mass spectrometry (MC-ICP-MS). Values of delta198/202Hg varied from 0.0-1.3 percent per thousand relative to a NIST SRM 1641d Hg solution. The typical external uncertainty of the delta values was 0.06 to 0.26 percent per thousand. Hg was introduced into the plasma as elemental Hg after reduction by sodium borohydride. A significant fractionation of lead isotopes was observed during the simultaneous generation of lead hydride, preventing normalization of the Hg isotope ratios using the measured 208/206Pb ratio. Hg ratios were instead corrected employing the simultaneously measured 205/203T1 ratio. Using a 10 ng ml(-1) Hg solution and 10 min of sampling, introducing 60 ng of Hg, the internal precision of the isotope ratio measurements was as low as 14 ppm. Absolute Hg ratios deviated from the representative IUPAC values by approximately 0.2% per u. This observation is explained by the inadequacy of the exponential law to correct for mass bias in MC-ICP-MS measurements. In the absence of a precisely characterized Hg isotope ratio standard, we were not able to determine unambiguously the absolute Hg ratios of the ore samples, highlighting the urgent need for certified standard materials.
...
PMID:High precision isotope ratio measurements of mercury isotopes in cinnabar ores using multi-collector inductively coupled plasma mass spectrometry. 1286 80

The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.
...
PMID:Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g(-1) levels. 1368 60

Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the Pb/Ca ratios in the enamel of deciduous incisors, a biomarker of in utero Pb exposure, using pelletized bone certified reference materials (CRMs) as calibrants. The detection limit for Pb by LA-ICP-MS was 11 microg kg(-1) demonstrating an adequate sensitivity for Pb in the teeth of unexposed individuals (0.1-10 mg kg(-1)). The precision for the Pb/Ca ratios in NIST SRM 1486 Bone Meal was 3.4%. The correlation between Pb/Ca ratios obtained by LA-ICP-MS and those obtained by a digestion method was highly significant. We found one point calibration by a CRM was applicable for the quantification of Pb in tooth enamel. This method will be valuable for the assessment of in utero Pb exposure levels.
...
PMID:Analysis of lead in tooth enamel by laser ablation-inductively coupled plasma-mass spectrometry. 1459 8

Two microwave digestion systems (open-focused and closed-pressurized) were tested for the mineralization of human brain and bovine liver (NIST SRM 1577a) as dissolution steps prior to the determination of 16 trace elements (Bi, Cd, Co, Cs, Cu, Fe, Hg, Mn, Mo, Pb, Rb, Sb, Sn, Sr, Tl, and Zn) by inductively coupled plasma mass spectrometry (ICP-MS). Digestion parameters (mass of sample, digestion mixture, and power/time steps) were optimized using temperature and pressure sensors. Digestions with the open-focused microwave system require larger volumes of conc. HNO(3) and 30% H(2)O(2) than digestions with the closed-pressurized system. Both systems produce correct results for the bovine liver samples. The concentrations obtained for the digests of the open-focused system tend to be less precise than the concentrations from the "closed-pressurized" digests. Because the "open-focused" digests must be diluted to 50 mL to bring the acid concentration to 0.7-2.0 mol/L required by the ICP-MS (closed-pressurized digests need to be diluted to only 20 mL), the detection limits for the system with the open-focused digestion are higher than for the system with the closed-pressurized digestor. The open-focused digestor cannot handle more than 150 mg brain tissue, whereas the closed-pressurized system can mineralize 470 mg. The latter method gave better results with brain tissue than the open-focused system. The preparation of brain tissue as reference material for the determination of trace elements in brain samples is described.
...
PMID:Microwave digestion methods for the determination of trace elements in brain and liver samples by inductively coupled plasma mass spectrometry. 1504 34


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>