Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:2.7.10.2 (focal adhesion kinase)
44,029 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A separation-preconcentration procedure based on the coprecipitation of cobalt(II) and manganese(II) ions with copper(II)-8-hydroxquinoline system has been developed. The analytical parameters including pH, amount of copper(II) as carrier element, amount of 8-hydroxquinoline, sample volume, etc., was investigated for the quantitative recoveries of Co(II) and Mn(II). No interferic effects were observed from the concomitant ions which are present in real samples. The detection limits for analyte ions by three sigma criteria were 0.86microgL(-1) for cobalt and 0.98microgL(-1) for manganese. The validation of the presented preconcentration procedure was performed by the analysis of NIST SRM 2711 Montana soil and GBW 07605 Tea certified reference materials. The procedure presented was applied to the analyte contents of real samples including natural waters and some food samples with successfully analytical results.
...
PMID:Copper(II)-8-hydroxquinoline coprecipitation system for preconcentration and separation of cobalt(II) and manganese(II) in real samples. 1732 5

The biosorption of copper(II), lead(II), iron(III) and cobalt(II) on Bacillus sphaericus-loaded Diaion SP-850 resin for preconcentration-separation of them have been investigated. The sorbed analytes on biosorbent were eluted by using 1 mol L(-1) HCl and analytes were determined by flame atomic absorption spectrometry. The influences of analytical parameters including amounts of pH, B. sphaericus, sample volume etc. on the quantitative recoveries of analytes were investigated. The effects of alkaline, earth alkaline ions and some metal ions on the retentions of the analytes on the biosorbent were also examined. Separation and preconcentration of Cu, Pb, Fe and Co ions from real samples was achieved quantitatively. The detection limits by 3 sigma for analyte ions were in the range of 0.20-0.75 microg L(-1) for aqueous samples and in the range of 2.5-9.4 ng g(-1) for solid samples. The validation of the procedure was performed by the analysis of the certified standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 2711 Montana soil and GBW 07605 Tea). The presented method was applied to the determination of analyte ions in green tea, black tea, cultivated mushroom, boiled wheat, rice and soil samples with successfully results.
...
PMID:Biosorption of copper(II), lead(II), iron(III) and cobalt(II) on Bacillus sphaericus-loaded Diaion SP-850 resin. 1738 50

Multiwalled carbon nanotubes (MWNTs) were used as solid phase extractor for Cu(II), Cd(II), Pb(II), Zn(II), Ni(II) and Co(II) ions as ammonium pyrrolidine dithiocarbamate (APDC) chelates, in the present study. The influences of the experimental parameters including pH of the solutions, amounts of MWNTs, amounts of APDC, eluent type and volume, sample volume etc. on the quantitative recoveries of analyte ions were investigated. The effects of matrix ions of natural waters and some transition metals on the recoveries of the analyte ions were also examined in the model solutions. Tests of addition/recovery for analyte ions in real samples were performed with satisfactorily results. The detection limits (3s) for the analyte ions were in the range of 0.30-0.60 microg l(-1). The concentrations of analytes in standard reference materials (NIST RM 8418 Wheat gluten, LGC 6010 Hard drinking water and NIST SRM 1515 Apple leaves) pretreated by the presented method were measured with FAAS and the analytical values were well agreed with the certified values and the reference values without the interference of major components. The presented method has been applied to the determination of analytes in food and environmental samples with satisfactory results.
...
PMID:Solid phase extraction of heavy metal ions in environmental samples on multiwalled carbon nanotubes. 1772 63

An analytical procedure fit for the simultaneous determination of copper (II), chromium(VI), thallium(I), lead(II), tin(II), antimony(III), and zinc(II) by square wave anodic stripping voltammetry (SWASV) in three interdependent environmental matrices involved in foods and food chain as meals, cereal plants and soils is described. The digestion of each matrix was carried out using a concentrated HCl-HNO3-H2SO4 (meals and cereal plants) and HCl-HNO3 (soils) acidic attack mixtures. 0.1 mol/L dibasic ammonium citrate pH 8.5 was employed as the supporting electrolyte. The voltammetric measurements were carried out using, as working electrode, a stationary hanging mercury drop electrode (HMDE) and a platinum electrode and an Ag/AgCl/KClsat electrode as auxiliary and reference electrodes, respectively. The analytical procedure was verified by the analyses of the standard reference materials: Wholemeal BCR-CRM 189, Tomato Leaves NIST-SRM 1573a and Montana Soil Moderately Elevated Traces NIST-SRM 2711. For all the elements in the certified matrix, the precision as repeatability, expressed as relative standard deviation (Sr %) was lower than 5%. The accuracy, expressed as percentage relative error (e %) was of the order of 3-7%, while the detection limits were in the range 0.015-0.103 microg/g. Once set up on the standard reference materials, the analytical procedure was transferred and applied to commercial meal samples, cereal plants and soils samples drawn in sites devoted to agricultural practice. A critical comparison with spectroscopic measurements is also discussed.
...
PMID:Analytical procedure for the simultaneous voltammetric determination of trace metals in food and environmental matrices. Critical comparison with atomic absorption spectroscopic measurements. 1782 23

A solid phase extraction (SPE) preconcentration system, coupled to a flame atomic absorption spectrometer (FAAS), was developed for the determination of copper(II), cadmium(II), lead(II), manganese(II), iron(III), nickel(II) and cobalt(II) ions at the microg L(-1) levels on Penicillium italicum-loaded on Sepabeads SP 70. The analytes were adsorbed on biosorbent at the pH range of 8.5-9.5. The adsorbed metals were eluted with 1 mol L(-1) HCl. The influences of the various analytical parameters including pH of the aqueous solutions, sample volume, flow rates were investigated for the retentions of the analyte ions. The recovery values are ranged from 95-102%. The influences of alkaline, earth alkaline and some transition metal ions were also discussed. Under the optimized conditions, the detection limits (3s, n=21) for analytes were in the range of 0.41microg L(-1) (cadmium) and 1.60microg L(-1) (iron). The standard reference materials (IAEA 336 Lichen, NIST SRM 1573a Tomato leaves) were analyzed to verify the proposed method. The method was successfully applied for the determinations of analytes in natural water, cultivated mushroom, lichen (Bryum capilare Hedw), moss (Homalothecium sericeum) and refined table salt samples.
...
PMID:A biosorption system for metal ions on Penicillium italicum-loaded on Sepabeads SP 70 prior to flame atomic absorption spectrometric determinations. 1782 83

A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min(-1), auxiliary gas flow of 0.2 L min(-1) and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted method developed is highly comparable with the microwave digestion method standardized by the United States Environmental Protection Agency (EPA-3052). The ultrasound-assisted digestion with a digestion solution of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 81%. One exception is arsenic which resulted in recoveries of about 60% only; however, it could be digested with good recovery (>90%) using a digestion solution of 5 mL of water and 5 mL of aqua regia. The major advantage of the ultrasound-assisted digestion over microwave digestion is the high treatment rate (30 samples simultaneously with a sonication time of 18 min).
...
PMID:An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical emission spectrometry. 1793 4

Four novel (64)Cu complexes ([(64)Cu(thp)(4)](+) (1), [(64)Cu(TPA)(4)](+) (2), [HC(CO(2))(pz(Me2))(2) (64)Cu(thp)(2)] (3) and [HC(CO(2))(tz)(2) (64)Cu(thp)(2)] (4), [where thp is tris(hydroxymethyl)phosphine, TPA is 1,3,5-triaza-7-phosphaadamantane, pz(Me2) is 3,5-dimethylpyrazole and tz is 1,2,4-triazole] were successfully synthesized and characterized. The complexes were produced in high radiochemical purity and yield (more than 98%) without the need for further purification. Their logP values and serum stabilities were measured and in vitro behavior was observed in cultured EMT-6 cells. The logP values (+/- standard deviation) obtained were -2.26 +/- 0.04 (1), 0.01 +/- 0.01 (2), -1.24 +/- 0.03 (3) and -2.06 +/- 0.03 (4). Complex 3 demonstrated the highest serum stability, with approximately 33% of the complex still intact after 1-h incubation. Complex 2 showed a rapid cell-association with EMT-6 cells, with more than 8.5% association at 2 h. This association was significantly higher (P < 0.001) than for the other three compounds after a 2-h incubation (1, 1.21%; 3, 0.63%; 4, 2.75%). Biodistribution and small-animal positron emission tomography/computed tomography was undertaken with 1 in mice bearing EMT-6 tumors. EMT-6 tumor uptake was high at 1 h (7.71 +/- 2.17 %ID/g) and decreased slowly over 24 h (4 h, 4.90 +/- 0.78 %ID/g; 24 h, 3.74 +/- 0.73 %ID/g). The PET/CT images show that the EMT-6 tumors can be visualized at all time points. In this proof-of-concept study, we have successfully synthesized and characterized a novel series of versatile water-soluble Cu(I) complexes containing monophosphine ligands. We also report the use of 1 as a building block for new radiopharmaceuticals, perhaps the first time such a method has been used in the production of copper radiopharmaceuticals.
...
PMID:Synthesis, in vitro and in vivo characterization of (64)Cu(I) complexes derived from hydrophilic tris(hydroxymethyl)phosphane and 1,3,5-triaza-7-phosphaadamantane ligands. 1804 51

A separation-preconcentration procedure based on the coprecipitation of lead(II) and chromium(III) ions with copper(II)-5-chloro-2-hydroxyaniline system has been developed. Effects of pH, sample volume and interferences on the recovery of the metal ions were investigated. The detection limits corresponding to three times the standard deviation of the blank were found to be 2.72 microg L(-1) for lead and 1.20 microg L(-1) for chromium. The preconcentration factor is 50. The effectiveness of the present method was assessed by determining analyte metals in GBW 07309 stream sediment and NIST SRM 1633b coal fly ash certified reference materials. The method was successfully applied to the determination of trace lead and chromium in environmental samples.
...
PMID:5-Chloro-2-hydroxyaniline-copper(II) coprecipitation system for preconcentration and separation of lead(II) and chromium(III) at trace levels. 1829 2

Bacillus thuringiensis israelensis loaded on Dowex optipore V-493 as new adsorbent for the separation-preconcentration of heavy metal ions has been proposed. The analytical conditions for the quantitative recoveries of copper(II), iron(III) and zinc(II) including pH, amounts of adsorbent, sample volume, etc. were investigated. The influences of alkaline and earth alkaline ions were also reported. The recovery values for the analytes are generally higher than 95%. The preconcentration factor was 37. The limit of detections of the analyte ions (k=3, N=21) were 1.14 microgL(-1) for copper, 2.01 microgL(-1) for iron and 0.14 microgL(-1) for zinc. The relative standard deviations of the determinations were found to be lower than 9%. The procedure was validated by analyzing copper, iron and zinc contents in two certified reference materials, NRCC-SLRS-4 Riverine water and NIST SRM 1515 Apple leaves. Agreements between the obtained results and the certified values were achieved. The developed preconcentration method was applied in the flame atomic absorption spectrometric determination of copper, iron and zinc in several samples including a multivitamin-multimineral tablet, dialysis solutions, natural waters and some food samples.
...
PMID:Solid-phase extraction of copper, iron and zinc ions on Bacillus thuringiensis israelensis loaded on Dowex optipore V-493. 1835 63

A coprecipitation method has been developed for the determination of Cr(III), Mn(II), Fe(III), Co(II), Cu(II), Cd(II) and Pb(II) ions in aqueous samples by flame atomic absorption spectrometry (FAAS) with the combination of pyridine, nickel(II) as a carrier element and potassium thiocyanate as an auxiliary complexing agent. The obtained coprecipitates were dissolved with nitric acid and measured by FAAS. The coprecipitation conditions, such as the effect of the pH, amounts of nickel, pyridine and potassium thiocyanate, sample volume, and the standing time of the precipitate formation were examined in detail. It was found that the metal ions studied were quantitatively coprecipitated with tetrakis(pyridine)-nickel(II)bis(thiocyanate) precipitate (TP-Ni-BT) in the pH range of 9.0 - 10.5. The reliability of the results was evaluated by recovery tests, using synthetic seawater solutions spiked with the analyte metal ions. The obtained recoveries ranged from 96 to 101% for all of the metal ions investigated. The proposed method was validated by analyses of two certified reference materials (NIST SRM 2711 Montana soil and HPS Certified Waste Water Trace Metals Lot #D532205). It was also successfully applied to seawater and dialysis solution samples. The detection limits (n = 25, 3s) were in the range of 0.01-2.44 microg l(-1) for the studied elements and the relative standard deviations were < or =6%, which indicated that this method could fully satisfy the requirements for analysis of such samples as seawater and dialysis solution having high salt contents.
...
PMID:Determination of heavy metals at sub-ppm levels in seawater and dialysis solutions by FAAS after tetrakis(pyridine)-nickel(II)bis(thiocyanate) coprecipitation. 1854 64


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>