Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:2.7.10.2 (
focal adhesion kinase
)
44,029
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The PVTx behavior for the x N-methylpyrrolidone (NMP) + (1 - x)
methanol
compressed liquid solvent is reported over the full composition range and within wide pressure and temperature ranges. The derived excess properties were analyzed in terms of structural effects and intermolecular interactions and revealed strong H-bonding heteroassociations between the two components. The cubic equations of state by Soave (
SRK
), Peng-Robinson (PR), Patel-Teja (PT), and Sako-Wu-Prausnitz (SWP), and the statistical associating fluid theory (SAFT) equation of state, combined with a number of selected mixing rules, were used to correlate and predict the behavior of both the pure components and mixed solvent. While the classical cubic equations of state were not successful in describing the properties of this system, the SWP equation of state and the SAFT yielded reasonably good results.
...
PMID:PVTx measurements of the N-methylpyrrolidone/methanol mixed solvent: cubic and SAFT EOS analyses. 1657 Oct 5
A method for determining organophosphate esters in air samples using C8 Empore solid phase extraction (SPE) membranes has been developed. After the sampling the analytes trapped in the membrane are completely desorbed with
methanol
, using an extraction cell connected online to the organic modifier channel of a HPLC gradient pump. The addition of water to the mobile phase prior to analytical chromatography ensures that the analytes are refocused and efficiently separated. Sampling with Empore SPE membranes enables the collection of analytes in both the vapour phase and particulate matter. During the air sampling procedure no losses were observed after 24 h of sampling, yielding a total volume of 14.4 m3, even for the most volatile compound used in this investigation (trimethylphosphate). Complete desorption was observed for all the organophosphate esters and recoveries were greater than 95%, with a relative standard deviation of less than 8%. The limits of detection ranged between 0.4 and 19 pg/m3. The effect of particulate matter on the extraction efficiency was investigated in detail by spiking the membranes with reference standard material. It was also found that the SPE membranes could be stored for at least 5 days at room temperature without any evidence of loss. The efficacy of the method was verified using real samples from different common indoor environments. Interestingly, significant quantities of several phosphate esters were found in a NIST standard reference material (urban dust,
SRM
1649a).
...
PMID:Air sampling with Empore solid phase extraction membranes and online single-channel desorption/liquid chromatography/mass spectrometry analysis: determination of volatile and semi-volatile organophosphate esters. 1693 77
Two independently developed liquid chromatography (LC) methods for the quantitative determination of biotin in multivitamin/multielement tablets (NIST Standard Reference Material 3280 (
SRM
3280)) are described. The methods use distinctly different tablet extraction solvents (
methanol
vs 1.5% aqueous formic acid) and analyte detection principles (mass spectrometry (MS) versus evaporative light-scattering detection (ELSD)) to ensure quantitative reliability. The use of different extraction and detection procedures allows cross-validation of the methods and enhances confidence in the final quantitative results. Both methods yield highly comparable results for the mean level of biotin (LC/MS = 26.5 mg/kg +/- 0.3 mg/kg (n = 12); LC/ELSD = 24.7 mg/kg +/- 1.7 mg/kg (n = 12)) in
SRM
3280, yet the methods differ considerably in their analytical characteristics. The isotope-dilution LC/MS method exhibits excellent linearity from 0.02 ng to 77 ng biotin on-column with a method limit of detection (LOD) and limit of quantification (LOQ) of 0.02 ng (S/N > 3) and 0.06 ng (S/N > 10) biotin on-column, respectively. The LC/ELSD method exhibits good linearity from 155 ng to 9900 ng biotin on-column with a method LOD and LOQ of 155 ng (S/N > 3) and 310 ng (S/N > 10) biotin on-column, respectively. Method performance data indicates that the LC/MS method is analytically superior to the LC/ELSD method; however, either method in combination with
SRM
3280 should provide quality assurance, accuracy, and traceability for biotin levels in multivitamin/multielement dietary supplements.
...
PMID:Improved liquid chromatography methods for the separation and quantification of biotin in NIST standard reference material 3280: multivitamin/multielement tablets. 1709 Jan 11
It is now well-recognized that the activating
JAK2
(V617F) mutation occurs in the majority of patients with polycythemia vera (PV) and approximately half of those with either essential thrombocythemia (ET) or myelofibrosis with myeloid metaplasia (MMM). Here we analyzed
JAK2
(V617F) mutation in 137 Chinese patients with myeloproliferative disorders by allele-specific polymerase chain reaction (PCR). DNA was extracted from
methanol
/acetic acid-fixed cells that had been routinely prepared for cytogenetic analysis. A single point mutation (Val617Phe) was identified in
JAK2
in 42 (73.7%) of 57 patients with PV, 40 (58.8%) of 68 with ET, and eight (66.7%) of 12 with MMM.
...
PMID:Analysis of JAK2(V617F) mutation in Chinese patients with myeloproliferative disorders. 1726 61
Polycyclic aromatic hydrocarbons (PAHs) with four to six rings are potent carcinogens. This study analyzed ten of the sixteen US EPA priority PAHs using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) in selected reaction monitoring mode with two ionization sources: positive atmospheric pressure chemical ionization (APCI+) or positive elecrtrospray ionization (ESI+) with tropylium post-column derivatization. Several factors were investigated, including mobile phases, stationary phases of columns and chromatographic temperature, to determine how optimal separation and sensitivity might be achieved.
Methanol
used as an organic mobile phase provided better sensitivities for most PAHs than acetonitrile, although some PAHs co-eluted. Acidic buffers did not increase analyte signals. Use of Restek Pinnacle II PAH columns (250 x 4.6 mm or 250 x 2.1 mm, 5 microm) with water/acetonitrile gradient at 27 degrees C made possible a good separation of the ten analytes. [M]+. were the best precursor ions in both APCI and ESI, although fluoranthene could not be detected in ESI mode when tropylium post-column derivatization was performed. [M-28]+ and [M-52]+ were the major product ions of PAHs after collision-induced dissociation, a result of neutral losses of C(2)H(4) and (C(2)H(2))(2), respectively. Chromatographic separation for PAH isomers was crucial because the mass spectra were so similar that even MS/MS could not distinguish them from each other. The recoveries of sample preparations of PAHs spiked onto air-sampling filters ranged between 77.5 and 106% with relative standard deviations between 1.1 and 15.9%. This method was validated by analyzing NIST
SRM
1649a (urban dust), producing results comparable with the certified PAH concentrations. The detection limits using APCI and ESI interfaces, defined as three times the noise levels, ranged between 0.23 and 0.83 ng and between 0.16 and 0.84 ng of on-column injection, respectively.
...
PMID:Analysis of polycyclic aromatic hydrocarbons by liquid chromatography/tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray ionization with tropylium post-column derivatization. 1793 49
An ion chromatography-inductively coupled plasma mass spectrometric (IC-ICP-MS) method for the speciation of selenium and tellurium compounds namely selenite [Se(IV)], selenate [Se(VI)], Se-methylselenocysteine (MeSeCys), selenomethione (SeMet), tellurite [Te(IV)] and tellurate [Te(VI)] is described. Chromatographic separation is performed in gradient elution mode using 0.5 mmol L(-1) ammonium citrate in 2%
methanol
(pH 3.7) and 20 mmol L(-1) ammonium citrate in 2%
methanol
(pH 8.0). The analyses are carried out using dynamic reaction cell (DRC) ICP-MS. The DRC conditions have also been optimized to obtain interference free measurements of (78)Se(+) and (80)Se(+) which are otherwise interfered by (38)Ar(40)Ar(+) and (40)Ar(40)Ar(+), respectively. The detection limits of the procedure are in the range 0.01-0.03 ng Se mL(-1) and 0.01-0.08 ng Te mL(-1), respectively. The accuracy of the method has been verified by comparing the sum of the concentrations of individual species obtained by the present procedure with the total concentration of the elements in two NIST SRMs Whole Milk Powder RM 8435 and Rice Flour
SRM
1568a. The selenium and tellurium species are extracted from milk powder and rice flour samples by using Protease XIV at 70 degrees C on a water bath for 30 min.
...
PMID:Determination of selenium and tellurium compounds in biological samples by ion chromatography dynamic reaction cell inductively coupled plasma mass spectrometry. 1819 46
In the present study, we developed a reference material (RM) using authentic hair samples for the determination of methamphetamine (MA) and its main metabolite, amphetamine (AP) in human hair. MA abusers' hair samples were collected, homogenized and finally bottled. The concentration of each bottle was determined using two extraction methods, agitation with 1% HCl in
methanol
at 38 degrees C and ultrasonication with
methanol
/5M HCl (20:1), followed by gas chromatography/mass spectrometry (GC-MS) after derivatization with trifluoroacetic anhydride (TFAA). Both analytical procedures were fully validated and their extraction efficiency was compared. The homogeneity of analytes was evaluated and their property values were determined with their uncertainties. The two methods were acceptable to analyze MA and AP in human hair through the validation and comparative studies using spiked and authentic hair samples as well as NIST
SRM
2379 certified reference material. Satisfying homogeneity was reached for MA and AP in the prepared RM. Finally, a human hair RM containing MA and AP is prepared at the level of 7.64+/-1.24 and 0.54+/-0.07 ng/mg, respectively. This material can be useful in forensic laboratories for internal quality control and external quality assurance.
...
PMID:Development of a reference material using methamphetamine abusers' hair samples for the determination of methamphetamine and amphetamine in hair. 1828 47
Eight polybrominated diphenyl ether (PBDE) congeners of primary interest to the US EPA were separated using reverse-phase liquid chromatography on an octadecylsilane column. BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, BDE-183, and BDE-209 were baseline-resolved under isocratic conditions in 92:8
methanol
/water (v/v). Negative-ion atmospheric pressure photoionization (NI-APPI) with a toluene dopant produced precursor ions corresponding to [M-Br+O](-) for the eight congeners studied. Each congener was quantified by tandem mass spectrometry through a unique multiple reaction monitoring (MRM) transition. On-column limits of detection were between 2.4 and 27.8 pg for the eight congeners studied, with an intra-day method precision of 9%. The LC/NI-APPI/MS/MS method was validated for the analysis of the eight PBDE congeners in NIST
SRM
2585 (Organics in House Dust). Pressurized liquid extraction (PLE) with subsequent LC/NI-APPI/MS/MS analysis afforded quantitative recovery for all eight PBDE congeners with recoveries ranging from 92.7 to 113%. The liquid-phase separation of the LC/NI-APPI/MS/MS method is not prone to the thermal degradation issues that plague splitless GC based analyses of highly brominated PBDEs such as BDE-209.
...
PMID:Analysis of polybrominated diphenyl ethers (PBDEs) by liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometry (LC/NI-APPI/MS/MS): application to house dust. 1850 59
Both (206)Pb-labeled trimethyllead (TML) and triethyllead (TEL) were synthesized from (206)Pb-enriched metallic Pb certified reference material (NIST
SRM
983) and iodomethane or iodoethane through a one-process reaction in a closed system using centrifuge tubes, respectively. Organolead compounds in an urban dust reference material (BCR CRM 605) were extracted with an acetic acid/
methanol
(1:1) solution, which was mechanically shaken for 24 h. After adjusting the pH of the extracted solution to pH 5, the extracted organolead compounds were derivatized by tetrabutylammonium tetrabutylborate (TATB) and measured with GC-ICPMS. The analytical results of TML and TEL for BCR CRM 605 were 8.22 +/- 0.04 microg kg(-1) (mean +/- standard deviation, n = 3) and 1.12 +/- 0.06 microg kg(-1), respectively. The analytical results of TML agreed well with the certified value (7.9 +/- 1.2 microg kg(-1)).
...
PMID:Simultaneous determination of trimethyl-and triethyllead in urban dust by species-specific isotope dilution/gas chromatography-inductively coupled plasma mass spectrometry. 1854 71
A novel method for cobalt preconcentration by cloud point extraction with on-line phase separation in a PTFE knotted reactor and further determination by electrothermal atomic absorption spectrometry (ETAAS) is proposed. The cloud point system was formed in the presence of non-ionic micelles of polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) and it was retained on the inner walls of a knotted reactor (KR). The surfactant rich-phase was removed from the knotted reactor with 75 microL of
methanol
acidified with 0.8 mol L(-1) nitric acid, directly into the dosing hole of the L'Vov graphite tube. An enrichment factor of 15 was obtained with a preconcentration time of 60 s, with respect to the direct determination of cobalt by ETAAS in aqueous solutions. The value of the detection limit for the preconcentration of 5 mL of sample solution was 10 ng L(-1). The precision, expressed as the relative standard deviation (R.S.D.), for 10 replicate determinations at 0.5 microg L(-1) Co level was 4.5%. Verification of the accuracy was carried out by analysis of a standard reference material (NIST
SRM
1640e "Trace elements in natural water"). The method was successfully applied to the determination of cobalt in drinking water samples.
...
PMID:Cloud point extraction for cobalt preconcentration with on-line phase separation in a knotted reactor followed by ETAAS determination in drinking waters. 1858 37
<< Previous
1
2
3
4
5
6
7
8
9
Next >>