Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:2.7.10.2 (focal adhesion kinase)
44,029 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The urine level of trace elements has been investigated in some normal adults under different workplace environments in Bangladesh. The samples were collected from 58 subjects, randomly selected from about 500 adults working in 10 different workshops and factories located in Dhaka city. Samples were analyzed by the external beam PIXE method. Proton beams of 2.5 MeV energy and 20 nA intensity were used for sample irradiations. For 40 microC irradiations, the concentration of 14 elements in total (K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, As, Br, Rb, Sr and Mo) in different groups were measured by comparison with a calibration curve obtained from the NBS Orchard Leaf standard (SRM 1571). The results from different workplaces are reported in terms of amount of excretion per unit volume of the sample collected. They, however, do not reflect the total daily excretion level of different subject groups.
...
PMID:Urine level of trace elements in some adults in Bangladesh under a workplace environment. 215 44

A patient whose leukaemic cells carried the rare t(7;11)(p15;p15) was diagnosed as having acute myelomonocytic leukaemia (AML-M4), and supports the association of this specific translocation with forms of acute myeloid leukaemia showing differentiation. Blast phase chronic myeloid leukaemia was excluded by lack of involvement of the ABL and BCR genes. Chromosome in situ hybridization studies showed that both the HRAS1 and INS genes were present on the terminal part of chromosome 11p which was translocated to chromosome 7p. Neither HRAS1 nor INS were structurally rearranged. Field inversion gel electrophoresis showed that a 400 kb fragment encompassing HRAS1 was structurally entire in leukaemic DNA. Because the INS gene, which was also translocated, is probably located proximal to HRAS1 on chromosome 11p, it is unlikely that HRAS1 was near the chromosome 11 breakpoint or involved in this leukaemia.
...
PMID:HRAS1 and INS genes are relocated but not structurally altered as a result of the t(7;11)(p15;p15) in a clone from a patient with acute myeloid leukaemia (M4). 271 71

Effects were compared of two methods of feed restriction (skip-a-day, SAD, vs. skip-two-days, STD) during 4 to 22 wk of age on the development, uniformity, and subsequent performance of White Rock pullets. The pullets, housed in cages, consumed the same amount of feed in both treatments. Nevertheless, body weights of birds kept under the STD feeding regimen were significantly (P less than .01) lower. This difference was still significant (P less than .05) at 35 wk of age. Flock uniformity at 11 wk of age was significantly (P less than .05) higher in pullets kept on the STD feeding program. Plasma glucose and corticosterone levels in fasted pullets and corticosterone levels in fed birds at the age of 21 wk were not affected by feeding regimen. However, the increase in plasma glucose after feeding was significantly (P less than .05) higher in pullets on the STD feeding program. Plasma corticosterone levels were consistently, and at times significantly (P less than .05), higher in fasted birds. Laying of the first egg was significantly (P less than .05) delayed in hens previously kept on the STD feeding regimen. Rate of egg production and egg weights up to 35 wk of age were not affected by the method of feed restriction.
...
PMID:Feed restriction in broiler breeder pullets: skip-a-day versus skip-two-days. 340 57

The U concentration in Standard Reference Material 2670 (Toxic Metals in Freeze-Dried Urine) and the urine of two preschool-age children were determined by measuring the chemically separated U by isotope dilution thermal ionization mass spectrometry using ion counting detection. This procedure can detect about 1% of the U atoms loaded into the mass spectrometer and has a total chemical blank of about 5 pg U. The U concentration in SRM 2670 was found to be 113 +/- 2 pg 238U/ml (1 s). At this concentration, a 1-ml sample is sufficient for a determination with a total uncertainty of less than 5%. The U concentrations in the two children were 3.1 +/- 0.9 and 3.6 +/- 0.9 pg 238U/g. These values suggest that the U concentration in urine of unexposed persons may be at this low level or lower.
...
PMID:Determining picogram quantities of U in human urine by thermal ionization mass spectrometry. 381 98

Fractional rates (% X day-1) of synthesis and degradation were determined by measuring the output of N tau-methylhistidine (MeHis) in the excreta at 4 and 8 weeks of age in the chicken. At 4 weeks of age, the fractional rate of synthesis of the meat-type stock was twice that of the egg-type stock (White Leghorn), but the fractional rates of synthesis at 8 weeks of age were similar (4.1-5.1% X day-1) among stocks. The fractional rate of degradation (1.3-1.5% X day-1) of the meat-type stock at 8 weeks of age was less than half the rate of the egg-type stock (2.9% X day-1). The fractional rates of synthesis and degradation at 4 weeks of age in the Satsuma native fowl were relatively high compared with those in the other stocks. In particular, the rate of degradation (8.6% X day-1) at 4 weeks of age was approximately twice that of other stocks. These results show that fractional rates of synthesis and degradation of muscle protein in the chicken differ among genetically diverse groups. The effect of changes in rates of synthesis and degradation on the change in fractional growth rate also differed. From regression coefficients (bks . FGR and bKd . FGR) of these rates in skeletal muscle protein on the fractional growth rate, it was recognized that the change in growth rate accompanies the changes in both synthesis and degradation in White Leghorn and commercial broilers but only the change in synthesis in White Plymouth Rock (dw) and Satsuma native fowl.
...
PMID:Variation among chicken stocks in the fractional rates of muscle protein synthesis and degradation. 649 31

We report an unusual hyperdiploid karyotype characterized by the simultaneous occurrence of tetrasomy 21 and trisomy 8 detected during early blastic evolution of a BCR-ABL-negative chronic myeloproliferative disorder. Blast cells from this patient showed a striking response to all-trans-retinoic acid (ATRA)-induced differentiation as evaluated by CD15 expression following in vitro exposure to this inducer. Our report represents the first description of such a composite karyotype in human hematologic malignancies.
...
PMID:Simultaneous occurrence of tetrasomy 21 and trisomy 8 in a patient with early blastic metamorphosis of chronic myeloproliferative disorder. 766 24

Supercritical fluid extraction (SFE) was compared to traditional Soxhlet extraction for the determination of polychlorinated biphenyl congeners in three standard reference materials: SRM 1941a (Organics in Marine Sediment), SRM 1944 (New York/New Jersey Waterway Sediment) and SRM 2974 [Organics in Mussel Tissue (Mytilus edulis) (Freeze-Dried)]. The concentrations determined using SFE compared well with the certified concentrations for the majority of the polychlorinated biphenyl congeners.
...
PMID:Comparison of supercritical fluid extraction and Soxhlet extraction for the determination of polychlorinated biphenyls in environmental matrix standard reference materials. 974 14

The application of open vessel focused microwave acid digestion is described for the preparation of geological and environmental samples for analysis using inductively coupled plasma-mass spectrometry (ICP-MS). The method is compared to conventional closed-vessel high pressure methods which are limited in the use of HF to break down silicates. Open-vessel acid digestion more conveniently enables the use of HF to remove Si from geological and plant samples as volatile SiF4, as well as evaporation-to-dryness and sequential acid addition during the procedure. Rock reference materials (G-2 granite, MRG-1 gabbros, SY-2 syenite, JA-1 andesite, and JB-2 and SRM-688 basalts) and plant reference materials (BCR and IAEA lichens, peach leaves, apple leaves, Durham wheat flour, and pine needles) were digested with results comparable to conventional hotplate digestion. The microwave digestion method gave poor results for granitic samples containing refractory minerals, however fusion was the preferred method of preparation for these samples. Sample preparation time was reduced from several days, using conventional hotplate digestion method, to one hour per sample using our microwave method.
...
PMID:Acid digestion of geological and environmental samples using open-vessel focused microwave digestion. 1193 12

Some of the most pernicious dangers of pollution arise from the presence of traces of toxic elements in the environment. In this work, we report on the determination of beryllium, arsenic, and selenium in the urine of steel production and steel quality control (QC) workers, in comparison to healthy control subjects. The urine samples were digested by a microwave system. Graphite furnace and hydride atomic absorption was used for the quantitative measurements of Be and As and Se, respectively. A quality control method for these procedures was established with concurrent analysis of Standard Trace Metals 7879 Level II and NIST SRM 2670 (Toxic Elements in Freeze Dried Urine). The results show that the urinary levels of these elements in steel production (As, 38.1 +/- 28.7 microg/L; Be, 1.58 +/- 0.46 microg/L, and Se, 69.2 +/- 28.8 +/- g/L) and in quality control workers (As, 23.9 +/- 18.1 microg/L; Be, 1.58 +/- 0.46 microg/L, and Se, 54.8 +/- 25.1 microg/L) are significantly higher than in the controls (As, 10.3 +/- 8.7 microg/L; Be, 0.83 +/- 0.46 microg/L; and Se, 32.3 +/- 13.5 microg/L). The possible connection of these elements with the etiology of disease and the possible role of selenium as a protective agent against the oncogenic and teratogenic action of other substances is discussed. We suggest the need for improvement of environmental conditions in the workplace through better ventilation and industrial hygiene practices.
...
PMID:Determination of urinary beryllium, arsenic, and selenium in steel production workers. 1235 Jan 33

Since 1982 standard calibration materials recommended for respirable crystalline silica analysis by the Mine Safety and Health Administration (MSHA) P7 Infrared Method and the National Institute for Occupational Safety and Health (NIOSH) X-ray Diffraction (XRD) Analytical Method 7500 have undergone minor changes in size distribution. However, a critical assumption has been made that the crystalline silica in ambient mine atmosphere respirable dust samples has also remained essentially unchanged in particle size distribution. Therefore, this work compared recent particle size distributions of underground coal mine dust and the silica component of these dusts with estimated aerodynamic particle size distributions of calibration standard materials MIN-U-SIL 5, Berkeley 5, and SRM 1878 used by two crystalline silica analysis techniques. Dust impactor sampling data for various locations in 13 underground coal mines were analyzed for the respirable mass median aerodynamic diameters. The data suggest that the MSHA P7 method will underestimate the silica content of the sample by at most 7.4% in the median size range 0.9 to 3.6 microm, and that it is unlikely one would obtain any significant error in the MSHA P7 method analysis when the method uses Berkeley 5, MIN-U-SIL 5, or SRM 1878 as a calibration standard material. The results suggest that the NIOSH Analytical Method 7500 would be more appropriate for a dust sample that is representative of the total (no cyclone classifier) rather than the respirable airborne dust, particularly because the mass fraction in the size range below 4 microm is usually a small percentage of the total airborne dust mass. However, NIOSH Analytical Method 7500 is likely to underestimate the silica content of an airborne respirable dust sample by only 5 to 10%. The results of this study also suggest that any changes that may have occurred in the median respirable size of airborne coal mine dust are not significant enough to cause any appreciable error in the current methods used for respirable crystalline silica analysis.
...
PMID:Comparison of coal mine dust size distributions and calibration standards for crystalline silica analysis. 1257 Mar 93


1 2 3 4 5 6 Next >>