Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:2.7.1.1 (hexokinase)
5,274 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

We describe a new, nonenzymatic method for determining serum glucose. This method is based upon the direct electrochemical oxidation of glucose by means of stable nickel-catalyst that is electrodeposited onto a lead dioxide electrode surface. Linear calibration plots are obtained for glucose in the 0.1 to 4500 mg/liter range. Values for 23 sera with glucose concentrations ranging from 300 to 4300 mg/liter showed a linear correlation coefficient of 0.996 when compared with values reported by a hospital laboratory using the hexokinase method. Typically a 25-microliter sample is used, but samples as small as 5 microliter have been successfully analyzed. The sample is added to 25.00 ml of pH 13 electrolyte containing 1 mmol of NiSO4 per liter; the amount of increase in anodic current comproses the analytical signal. For 20 repetitive analyses of a serum specimen, the CV was less than 4%. Ascorbic acid is rapidly decomposed in the electrolyte used and thus does not interfere. Uric acid is inactive at the concentrations present in serum samples. The sensitivity and simplicity of the new method suggest it as an alternative to currently available procedures.
...
PMID:Amperometric nonenzymatic determination of serum glucose by means of a nickel-catalyst electrode. 63 Jul 6

Nitrogen mustard (NH2) and Nor-nitrogen mustard (Nor-HN2) both inhibit the polymerization of deoxyhemoglobin S in solution and in intact erythrocytes. Metabolic studies were undertaken to determine the feasability of an extracorporeal treatment with these or related agents. Glucose utilization, hexose monophosphate shunt activity, methemoglobin reduction, and incubation with acetylphenylhydrazine for Heinz body formation were performed, as well as specific assays for hexokinase, pyruvate kinase, glucose-6-phosphate dehydrogenase, glutathione reductase, ATP, reduced glutathione (GSH), and survival of autologous mustard-treated cells in rabbits. HN2 was found to enter red cells rapidly and bind to intracellular contents. Metabolic studies revealed no significant inhibition or alteration of function by Nor-HN2 at 10 mg/ml of whole blood. Rabbit red cell survival was also normal. HN2, however, inhibited glutathione reductase and blocked the free sulfhydryl group of GSH by forming serveral addition products of alkylated GSH. Heinz body test with acetylphenylhydrazine became positive in HN2-treated cells, and rabbit red cell survival was shortened considerably in the concentration range used to inhibit sickling. Ascorbic acid stimulation of the hexose shunt pathway was inhibited by HN2, but methylene blue stimulation remained unaffected. 14-C-HN2 remains bound to red cells in vivo, and the disappearance of radioactivity is similar to that found with 14-C-DFP (disopropylfluorophosphate). Oxygen affinity of both HN2 and Nor-HN2 treated human red cells remains virtually the same as that found in control samples. It is concluded that Nor-HN2 may be a suitable agent for an extracorporeal therapy, and that each mustard needs to be evaluated individually for its antisickling effects and its suitability for extracorporeal use.
...
PMID:Metabolic effects of antisickling amounts of nitrogen and nor-nitrogen mustard on rabbit and human erythrocytes. 112 27

Diabur-test 5000, a new test strip for estimation of urinary glucose, was compared with the hexokinase glucose-6-phosphate dehydrogenase method in more than 2500 urine samples. By combination of two test ranges glucose concentrations of up to 5% can be detected by the strip test. After a reading time of 2 minutes, very precise estimation of urinary glucose is possible in eight steps from negative to 5%. False estimations of more than one color step virtually do not occur. Ketone bodies, salicylic acid and several antibiotics do not influence the test strip. Ascorbic acid shows a slight influence only in concentrations above 40 mg/dl. This influence disappears with glucose concentrations of more than 0.5%. Good correlation with the reference method, wide range of readings and simple handling make the test strip suited for the laboratory and particularly for self control of diabetic patients.
...
PMID:[Diabur-Test 5000 - a new test strip for urinary sugar control in diabetic patients (author's transl)]. 705 64