Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:2.7.1.1 (hexokinase)
5,274 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Small-bore ("Autozyme") tubes with immobilized enzymes at the inner wall have been developed and studied for application in the Technicon "SMAC" high-speed continuous-flow biochemical analyzer. Tubes coated with glucose oxidase (D-glucose:oxygen oxidoreductase, EC 1.1.3.4) have been prepared for the assay of glucose, with colorimetric assay of the hydrogen peroxide produced; tubes coated with glycerol kinase (ATP:glycerol phosphotransferase, EC 2.7.1.30) for the enzymatic assay of triglycerides; tubes coated with hexokinase (ATP:D-hexose-6-phosphotransferase, EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (D-glucose-6-phosphate:NAD+ oxidoreductase EC 1.1.1.49) for the measurement of ATP, an intermediate product in assays for creatine kinase. With use of 10-15 cm lengths of Autozyme tube and SMAC hydraulics (150 samples per hour), assay sensitivity and carryover were similar to values for the corresponding free-enzyme methods. These immobilized enzymes were sufficiently stable for one to eight weeks of continuous use before replacemnt. We conclude that suitable bound-enzyme tubes can replace either single or multiple free-enzyme reagents in many continuous-flow assays at high sampling rates.
...
PMID:Continuous-flow analysis for glucose, triglycerides, and ATP with immobilized enzymes in tubular form. 1 65

We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were compared to those by the National Glucose Reference Method. The upper limits of the total error estimate (a combination of random and systematic errors) were 76, 74, and 125 mg/liter at concentrations of 500, 1200, and 3000 mg/liter, respectively. The error estimates were less than allowable errors based on medical usefulness; thus the method was judged to perform acceptably with respect to the Reference Method. We also present performance data for the routine SMAC glucose oxidase (EC 1.1.3.4)/Peroxidase (EC 1.11.1.7) 3-methyl-2-benzothianolinone hydrazone-N,N-dimethylaniline method, the direct hexokinase method with the Du Pont aca, and the glucose oxidase oxygen-rate method with the Beckman Glucose Analyzer.
...
PMID:Evaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC. 65 1