Query: EC:2.7.1.1 (hexokinase)
5,274 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The determination of capillary blood glucose after deproteinization using the aca is described. The method, which uses the hexokinase/glucose-6-phosphate dehydrogenase reaction, is compared with the glucose dehydrogenase method. The comparison shows that glucose values measured in capillary blood are essentially the same in both methods. The requirements for quality control are fulfilled. The method is not influenced by hemolysis, bilirubinemia, and hypertriglyceridemia.
...
PMID:[The determination of capillary blood glucose using the automatic clinical analyzer (aca) Dupont (author's transl)]. 64 50

We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were compared to those by the National Glucose Reference Method. The upper limits of the total error estimate (a combination of random and systematic errors) were 76, 74, and 125 mg/liter at concentrations of 500, 1200, and 3000 mg/liter, respectively. The error estimates were less than allowable errors based on medical usefulness; thus the method was judged to perform acceptably with respect to the Reference Method. We also present performance data for the routine SMAC glucose oxidase (EC 1.1.3.4)/Peroxidase (EC 1.11.1.7) 3-methyl-2-benzothianolinone hydrazone-N,N-dimethylaniline method, the direct hexokinase method with the Du Pont aca, and the glucose oxidase oxygen-rate method with the Beckman Glucose Analyzer.
...
PMID:Evaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC. 65 1

This report describes an interlaboratory comparison of enzymatic serum glucose methods as currently applied in several instrumental adaptations. Four spectrophotometric, hexokinase-based methods used with the Du Pont "aca," the Abbott "Bichromatic Analyzer," the Aminco "Rotochem," and the Technicon "AutoAnalyzer ll" were compared with glucose oxidase-based methods as used with the Beckman "Glucose Analyzer" and the "AutoAnalyzer ll." We analyzed both normal samples and samples that contained potential interfering substances or were otherwise abnormal. Although all methods were satisfactorily precise, methodological bias was noted in several cases, particularly with abnormal specimens. The hexokinase-based methods were generally more variable. The most consistent data were obtained from the two glucose oxidase methods and the Du Pont aca. Results of this study comprise part of the background information required for development of an accurate glucose reference method under the auspices of the AACC Standards Committee.
...
PMID:Interlaboratory comparison of enzymatic methods for serum glucose determination. 111 45