Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:2.4.1.14 (
SPS
)
813
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Reversible and differential multisite protein phosphorylation is an important mechanism controlling the activity of cellular proteins. Here we describe a robust and highly selective approach for the identification and relative quantification of site-specific phosphorylation events. This integrated strategy has three major parts: visualisation of phosphorylated proteins using fluorescently stained polyacrylamide gels, determination of the phosphorylation site(s) using automatic MS3 triggered by the loss of phosphoric acid, and relative quantification of phosphorylation by integrating
MS2
- and MS3-extracted ion traces using a fast-scanning, linear ion trap mass spectrometer. As a test case, recombinant
sucrose-phosphate synthase
(
SPS
) from Arabidopsis thaliana (At5g1110) was used for identification and quantification of site-specific phosphorylation. The identified phosphorylation site of the actively expressed protein coincides with the major regulatory in vivo phosphorylation site in spinach
SPS
. Site-specific differential in vitro phosphorylation of native protein was demonstrated after incubation of the recombinant protein with cold-adapted plant leaf extracts from A. thaliana, suggesting regulatory phosphorylation events of this key enzyme under stress response.
...
PMID:An integrated strategy for identification and relative quantification of site-specific protein phosphorylation using liquid chromatography coupled to MS2/MS3. 1628 31
Multiplexed quantitation via isobaric chemical tags (e.g., tandem mass tags (TMT) and isobaric tags for relative and absolute quantitation (iTRAQ)) has the potential to revolutionize quantitative proteomics. However, until recently the utility of these tags was questionable due to reporter ion ratio distortion resulting from fragmentation of coisolated interfering species. These interfering signals can be negated through additional gas-phase manipulations (e.g., MS/MS/MS (MS3) and proton-transfer reactions (PTR)). These methods, however, have a significant sensitivity penalty. Using isolation waveforms with multiple frequency notches (i.e., synchronous precursor selection,
SPS
), we coisolated and cofragmented multiple
MS2
fragment ions, thereby increasing the number of reporter ions in the MS3 spectrum 10-fold over the standard MS3 method (i.e., MultiNotch MS3). By increasing the reporter ion signals, this method improves the dynamic range of reporter ion quantitation, reduces reporter ion signal variance, and ultimately produces more high-quality quantitative measurements. To demonstrate utility, we analyzed biological triplicates of eight colon cancer cell lines using the MultiNotch MS3 method. Across all the replicates we quantified 8,378 proteins in union and 6,168 proteins in common. Taking into account that each of these quantified proteins contains eight distinct cell-line measurements, this data set encompasses 174,704 quantitative ratios each measured in triplicate across the biological replicates. Herein, we demonstrate that the MultiNotch MS3 method uniquely combines multiplexing capacity with quantitative sensitivity and accuracy, drastically increasing the informational value obtainable from proteomic experiments.
...
PMID:MultiNotch MS3 enables accurate, sensitive, and multiplexed detection of differential expression across cancer cell line proteomes. 2492 32
Protein abundance profiling using isobaric labeling is a well-established quantitative mass spectrometry technique. However, ratio distortion resulting from coisolated and cofragmented ions, commonly referred to as interference, remains a drawback of this strategy. Tribrid mass spectrometers, such as the Orbitrap Fusion and the Orbitrap Fusion Lumos with a triple mass analyzer configuration, facilitate methods (namely,
SPS
-MS3) that can help alleviate interference. However, few standards are available to measure interference and thereby aid in method development. Here we introduce the TKO6 standard that assesses ion interference and is designed specifically for data acquired at low (unit) mass resolution. We use TKO6 to compare interference in
MS2
- versus MS3-based quantitation methods, data acquisition methods of different lengths, and ion-trap-based tandem mass tag reporter ion analysis (IT-MS3) with conventional Orbitrap-based analysis (OT-MS3). We show that the TKO6 standard is a valuable tool for assessing quantification accuracy in isobaric-tag-based analyses.
...
PMID:TKO6: A Peptide Standard To Assess Interference for Unit-Resolved Isobaric Labeling Platforms. 3048 Oct 31
Regulation of protein N-glycosylation is essential in human cells. However, large-scale, accurate, and site-specific quantification of glycosylation is still technically challenging. We here introduce SugarQuant, an integrated mass spectrometry-based pipeline comprising protein aggregation capture (PAC)-based sample preparation, multi-notch MS3 acquisition (Glyco-
SPS
-MS3) and a data-processing tool (GlycoBinder) that enables confident identification and quantification of intact glycopeptides in complex biological samples. PAC significantly reduces sample-handling time without compromising sensitivity. Glyco-
SPS
-MS3 combines high-resolution
MS2
and MS3 scans, resulting in enhanced reporter signals of isobaric mass tags, improved detection of N-glycopeptide fragments, and lowered interference in multiplexed quantification. GlycoBinder enables streamlined processing of Glyco-
SPS
-MS3 data, followed by a two-step database search, which increases the identification rates of glycopeptides by 22% compared with conventional strategies. We apply SugarQuant to identify and quantify more than 5,000 unique glycoforms in Burkitt's lymphoma cells, and determine site-specific glycosylation changes that occurred upon inhibition of fucosylation at high confidence.
...
PMID:A streamlined pipeline for multiplexed quantitative site-specific N-glycoproteomics. 3307 10
Isobaric tagging is a powerful strategy for global proteome profiling. A caveat of isobaric-tag-based quantification is "interference", which may be caused by coeluting peptides that are coisolated, cofragmented, and coanalyzed, thereby confounding quantitative accuracy. Here, we present a two-proteome standard that challenges the mass spectrometer to measure a range of protein abundance ratios in a background of potential interference. The HYpro16 standard consists of tandem mass tag (TMT) pro16-labeled human peptides at a 1:1 ratio across all channels into which is spiked TMTpro16-labeled yeast peptides in triplicate at 20:1, 10:1, 4:1, and 2:1 ratios. We showcase the HYpro16 standard by (1) altering the
MS2
isolation window width and (2) examining different data acquisition methods (hrMS2,
SPS
-MS3, RTS-MS3). Our data illustrate that wider isolation widths moderately increase the TMT signal, the benefits of which are offset by decreased ratio accuracy. We also show that using real-time database searching (RTS)-MS3 resulted in the most accurate ratios. Additionally, the number of quantified yeast proteins using RTS-MS3 approaches that of hrMS2 when using a yeast-specific database for real-time searching. In short, this quality control standard allows for the assessment of multiple quantitative measurements within a single run, which can be compared across instruments to benchmark and track performance.
...
PMID:HYpro16: A Two-Proteome Mixture to Assess Interference in Isobaric Tag-Based Sample Multiplexing Experiments. 3317 40