Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:2.3.1.108 (TAT)
2,389 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

In this article, the clinical experience with a cardiopulmonary bypass (CPB) using a newly developed hollow fiber oxygenator with an ultra-thin layer of silicone is reported. A comparative study of biocompatibility between the new oxygenator and a heparin coated oxygenator is also described. The CPB was performed with a silicone coated oxygenator, Mera Excelung Binding Prim HPO 15 H-C (Group I, n = 6) or Binding Prim HPO 25 H-C (Group II, n = 10) (Senko Medical Instrument Mfg., Tokyo, Japan). Air could be vented through the silicone coated hollow fibers, and it was easy to prime the circuits. The CPB duration was 101 +/- 37 min and 170 +/- 64 min for Groups I and II, respectively. There were no deaths and no complications from CPB. Partial arterial pressure of O2 levels 60 minutes after the start of CPB were 529 +/- 28 mm Hg and 529 +/- 28 mmHg for Group I and II, respectively. Partial arterial pressure of CO2 levels 60 min after the start of CPB were 36.4 +/- 4.6 mmHg and 39.4 +/- 4.4 mmHg, respectively. Plasma free hemoglobin at 60 min was 33.5 +/- 17.2 mg/ dL and 46.7 +/- 26.1 mg/dL for Groups I and II, respectively. As an evaluation of biocompatibility, the effects of the new oxygenator on platelet activation (GP Ib, IIb/IIIa), coagulation (TAT), fibrinolysis (PIC), and inflammatory response (C3a, granulocyte elastase) were investigated during CPB and comparing to those of the heparin coated oxygenator. There were no significant differences in GP Ib, GP IIb/IIa, TAT, PIC, and granulocyte elastase between the two oxygenators. However, 60 min after the start of CPB, the C3a was significantly lower for the new oxygenator group than for the heparin coated oxygenator group (p < 0.03). The new oxygenator showed good gas transfer, low hemolysis, and good biocompatibility. Because of its durability and good biocompatibility, the new oxygenator was determined to be suitable for prolonged extra corporeal circulation.
...
PMID:Clinical evaluation of a silicone coated hollow fiber oxygenator. 936 Jan 43

Intracellular delivery is a prerequisite for the efficacy of many pharmaceutical proteins. Herein, vitamin B6 (pyridoxal-5'-phosphate, PLP) functionalized calcium phosphate (CP) is used as the bio-recyclable nanocarrier for delivery of proteins into cells. Proteins could be loaded on/released from PLP-CP via formation/hydrolysis of pH sensitive aldimine bridging lysine and surface-displayed PLP. The loaded proteins could be delivered into the cytosol of HeLa, HepG2 and L929 cells where the carrier could be metabolized into endogenous metabolites of Ca2+, HPO4 2-, and vitamin B6. PLP-CP mediated cell transduction is 10-40 folds more efficient than TAT which is a widely used cell penetrating peptide, demonstrating the utility of PLP-CP as the traceless platform for high-efficiency delivery of proteins into mammalian cells.
...
PMID:Traceless protein delivery with an efficient recyclable nanocarrier. 3248 60