Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:1.8.1.4 (
diaphorase
)
2,754
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A sample of colonies from the Clarke-
Carbon
ColE1-Escherichia coli DNA plasmid gene bank was screened by conjugation for complementation of the
lipoamide dehydrogenase
lesion of a deletion strain lacking all components of the pyruvate dehydrogenase complex, delta (aroP aceE aceF lpd). Two ColE1-lpd+ hybrid plasmids were identified: pGS2 (ColE1-ace lpd+; 24 kb) and pGS5 (ColE1-lpd+; 14 kb). Enzymological studies confirmed that pGS2 expressed all the activities of the pyruvate dehydrogenase complex, whereas pGS5 expressed the
lipoamide dehydrogenase
and acetyltransferase activities (the latter from a ColE1 promoter). These and other plasmids were used to construct a 47-site (15 enzymes) restriction map for a 24.2 kb segment of bacterial DNA in the nadC-lpd region. A further 13 sites (six enzymes) were defined in a 5.4 kb sub-segment containing the lpd gene. lambda phage derivatives containing specific fragments were constructed and used in transduction studies which located the ace and lpd genes in a 7.78 kb sub-segment flanked by AccI and NruI sites.
...
PMID:Hybrid plasmids containing the pyruvate dehydrogenase complex genes and gene-DNA relationships in the 2 to 3 minute region of the Escherichia coli chromosome. 630 28
Microbiosensors based on carbon and and platinum fibers are described.
Carbon
fibers were used to construct microelectrodes of 7 microm diameter. Electrochemical operations for pre-electrolysis and measuring were examined for the highly sensitive determination of hydrogen peroxide. A triangular potential (-2 to +2V vs Ag/AgCl) was applied before measuring each pair of double pulses (first pulse: 750 mV; second pulse: 1100 mV). The determination limit was 0.1 microM of hydrogen peroxide. The reproducible determination of hydrogen peroxide is possible even in samples containing albumin protein. The separation of hydrogen peroxide from ascorbic acid is also possible because the oxidation potential of ascorbic acid is different from that of hydrogen peroxide. An acetylcholine microsensor was fabricated by immobilizing acetylcholine esterase and choline oxidase on the carbon fiber by entrapment with poly(vinyl alcohol)-quarternized stilbazole (PVA-SbQ). This sensor gave a linear calibration plot for the range 0.1-1.0 mM with a linear correlation coefficient of 0.9842. Glucose oxidase (GOD) and glucose dehydrogenase (GDH) immobilized cylindrical platinum microelectrodes were fabricated, and their characteristics were evaluated, respectively, by using 1,4-benzoquinone (BQ) and ferricyanide as electron mediators. Each enzyme was immobilized by using PVA-SbQ on a cylindrical microelectrode of 2 microm diameter. A linear range in the calibration curve of the GOD-based glucose microsensor was observed to be wider than that obtained using a disk electrode of 1 mm diameter. The mediated response of the 2 microm glucose sensor was compared with the response resulting from hydrogen peroxide detection. This result showed that a higher response and a wider linear range were observed with highly concentrated mediator. A much higher response of the GDH immobilized 2 microm microelectrode was obtained when not only ferricyanide but also
diaphorase
was employed to reoxidize the NADH produced by the enzyme reaction of GDH. The GHD-based glucose microsensor was found to be unaffected by the concentration of dissolved oxygen.
...
PMID:Microbiosensors for acetylcholine and glucose. 835 77