Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:1.6.5.2 (NQO1)
6,196 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

alpha-Glycerophosphate oxidase, in a strain of Streptococcus faecium, was found to be adaptive to aerated conditions of growth. The enzyme was purified and found to mediate electron transfer from alpha-glycerophosphate to O(2), with the production of stoichiometric concentrations of H(2)O(2) and dihydroxyacetone phosphate. The enzyme is an anionic flavoprotein, with flavine adenine dinucleotide as the apparent prosthetic group. By manometric methods, a K(m) of 6 x 10(-3)m, with reference to substrate concentration, was obtained. An active reduced nicotinamide adenine dinucleotide diaphorase was closely associated with this enzyme in chromatographic mobility on ECTEOLA-cellulose. The purified alpha-glycerophosphate oxidase was not inhibited by KCN, azide, or sulfhydryl reagents, nor was it stimulated by alpha-lipoate, yeast extract, or other supplements.
...
PMID:Alpha-glycerophosphate oxidase in Streptococcus faecium F 24. 578 98

The construction and performance of integrated amperometric biosensors for the determination of glycerol are reported. Two different biosensor configurations have been evaluated: one based on the glycerol dehydrogenase/diaphorase (GDH/DP) bienzyme system, and another using glycerol kinase/glycerol-3-phosphate oxidase/peroxidase (GK/GPOx/HRP). Both enzyme systems were immobilized together with the mediator tetrathiafulvalene (TTF) on a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode by using a dialysis membrane. The electrochemical oxidation of TTF at +150mV (vs. Ag/AgCl), and the reduction of TTF(+) at 0mV were used for the monitoring of the enzyme reactions for the bienzyme and trienzyme configurations, respectively. Experimental variables concerning both the biosensors composition and the working conditions were optimized for each configuration. A good repeatability of the measurements with no need of cleaning or pretreatment of the biosensors was obtained in both cases. After 51 days of use, the GDH/DP biosensor still exhibited 87% of the original sensitivity, while the GK/GPOx/HRP biosensor yielded a 46% of the original response after 8 days. Calibration graphs for glycerol with linear ranges of 1.0x10(-6) to 2.0x10(-5) or 1.0x10(-6) to 1.0x10(-5)M glycerol and sensitivities of 1214+/-21 or 1460+/-34microAM(-1) were obtained with GDH/DP and GK/GPOx/HRP biosensors, respectively. The calculated detection limits were 4.0x10(-7) and 3.1x10(-7)M, respectively. The biosensors exhibited a great sensitivity with no significant interferences in the analysis of wines. The biosensors were applied to the determination of glycerol in 12 different wines and the results advantageously compared with those provided by a commercial enzyme kit.
...
PMID:Integrated multienzyme electrochemical biosensors for the determination of glycerol in wines. 1826 15