Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:1.6.5.2 (NQO1)
6,196 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

We describe two fully enzymic methods, fluorometric and colorimetric, for determination of triglycerides (triacylglycerols) in serum. Samples are incubated with microbial lipase for 10 min, and the glycerol released from the triglycerides is oxidized by NAD+ in the presence of glycerol dehydrogenase. In the fluorometric method, the resulting NADH is in turn oxidized by resazurin as catalyzed by diaphorase to form resorufin, a highly fluorescent compound. In the colorimetric method, the NADH is oxidized by coupling with a tetrazolium salt/diaphorase system to form formazan, a highly colored compound. Calibration curves, constructed by plotting change in fluorescence or absorbance vs concentration of triglycerides, were linear up to 6 and 5 g of triglycerides per liter of serum for the fluorometric and colorimetric methods, respectively. The assays require only 5 and 15 microL of serum for fluorometry and colorimetry, respectively. The CV was 0.59% for the fluorometric method, 0.91% for the colorimetric procedure. The time for analysis for either method is less than 15 min. The results correlate well with those obtained by the Dow Diagnostic Kit method, a colorimetric method in which glycerol kinase and glycerol-1-phosphate dehydrogenase form NADH from ATP and NAD+ in the presence of glycerol and glycerol 1-phosphate.
...
PMID:Fluorometric and colorimetric enzymic determination of triglycerides (triacylglycerols) in serum. 689 89

The construction and performance of integrated amperometric biosensors for the determination of glycerol are reported. Two different biosensor configurations have been evaluated: one based on the glycerol dehydrogenase/diaphorase (GDH/DP) bienzyme system, and another using glycerol kinase/glycerol-3-phosphate oxidase/peroxidase (GK/GPOx/HRP). Both enzyme systems were immobilized together with the mediator tetrathiafulvalene (TTF) on a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode by using a dialysis membrane. The electrochemical oxidation of TTF at +150mV (vs. Ag/AgCl), and the reduction of TTF(+) at 0mV were used for the monitoring of the enzyme reactions for the bienzyme and trienzyme configurations, respectively. Experimental variables concerning both the biosensors composition and the working conditions were optimized for each configuration. A good repeatability of the measurements with no need of cleaning or pretreatment of the biosensors was obtained in both cases. After 51 days of use, the GDH/DP biosensor still exhibited 87% of the original sensitivity, while the GK/GPOx/HRP biosensor yielded a 46% of the original response after 8 days. Calibration graphs for glycerol with linear ranges of 1.0x10(-6) to 2.0x10(-5) or 1.0x10(-6) to 1.0x10(-5)M glycerol and sensitivities of 1214+/-21 or 1460+/-34microAM(-1) were obtained with GDH/DP and GK/GPOx/HRP biosensors, respectively. The calculated detection limits were 4.0x10(-7) and 3.1x10(-7)M, respectively. The biosensors exhibited a great sensitivity with no significant interferences in the analysis of wines. The biosensors were applied to the determination of glycerol in 12 different wines and the results advantageously compared with those provided by a commercial enzyme kit.
...
PMID:Integrated multienzyme electrochemical biosensors for the determination of glycerol in wines. 1826 15

n instrument for the automatic quantification of glycerol in grapes has been developed. We verify here that this analyte can be used as a benchmark of a serious disease affecting the grapevines, namely Botrytis cinerea. The core of the instrument is an amperometric biosensor consisting of a disposable screen printed electrode, generating the analytical signal thanks to a bi-enzymatic process involving glycerol dehydrogenase and diaphorase. The full automation of the analysis is realised by three micropumps and a microprocessor under control of a personal computer. The pumps allow the correct and constant dilution of the grape juice with a buffer solution also containing [Fe(CN)6]3- redox mediator and the injection of NAD+ cofactor when the baseline signal reaches a steady state; the instrument leads to automated reading of the analytical signal and the consequent data treatment. Although the analytical method is based on an amperometric technique that, owing to heavy matrix effects, usually requires an internal calibration, the analyses indicate that a unique external calibration is suitable for giving accurate responses for any grapes, both white and black ones.
...
PMID:Development of a sensor system for the determination of sanitary quality of grapes. 2356 25