Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:1.6.5.2 (
NQO1
)
6,196
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
We describe a fully enzymic method for manual and continuous-flow colorimetric assay of triacylglycerols (triglycerides) in serum. Triglycerides are enzymically hydrolyzed in 10 min by lipase and microbial esterase. The resulting free glycerol is measured enzymically by
glycerol kinase
and glycerol-3-phosphate dehydrogenase. The NADH so formed is oxidized by coupling with a tetrazolium salt/
diaphorase
system. The test follows Beer's law to 8 g/L, and the final color is stable for at least 1 h for serum, 15 min for aqueous triolein standards. The manual assay requires only 25 microliter of serum and few manipulations. A specific triolein standard was developed for calibrating the manual method. For the continuous-flow method, calibration is made with four concentrations of glycerol standard. The procedure is sensitive, has good precision and accuracy, and gives results that compare well with chemical and enzymic commercial kit methods.
...
PMID:Manual and continuous-flow colorimetry of triacylglycerols by a fully enzymic method. 75 21
We describe two fully enzymic methods, fluorometric and colorimetric, for determination of triglycerides (triacylglycerols) in serum. Samples are incubated with microbial lipase for 10 min, and the glycerol released from the triglycerides is oxidized by NAD+ in the presence of glycerol dehydrogenase. In the fluorometric method, the resulting NADH is in turn oxidized by resazurin as catalyzed by
diaphorase
to form resorufin, a highly fluorescent compound. In the colorimetric method, the NADH is oxidized by coupling with a tetrazolium salt/
diaphorase
system to form formazan, a highly colored compound. Calibration curves, constructed by plotting change in fluorescence or absorbance vs concentration of triglycerides, were linear up to 6 and 5 g of triglycerides per liter of serum for the fluorometric and colorimetric methods, respectively. The assays require only 5 and 15 microL of serum for fluorometry and colorimetry, respectively. The CV was 0.59% for the fluorometric method, 0.91% for the colorimetric procedure. The time for analysis for either method is less than 15 min. The results correlate well with those obtained by the Dow Diagnostic Kit method, a colorimetric method in which
glycerol kinase
and glycerol-1-phosphate dehydrogenase form NADH from ATP and NAD+ in the presence of glycerol and glycerol 1-phosphate.
...
PMID:Fluorometric and colorimetric enzymic determination of triglycerides (triacylglycerols) in serum. 689 89
The construction and performance of integrated amperometric biosensors for the determination of glycerol are reported. Two different biosensor configurations have been evaluated: one based on the glycerol dehydrogenase/
diaphorase
(GDH/DP) bienzyme system, and another using
glycerol kinase
/glycerol-3-phosphate oxidase/peroxidase (GK/GPOx/HRP). Both enzyme systems were immobilized together with the mediator tetrathiafulvalene (TTF) on a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode by using a dialysis membrane. The electrochemical oxidation of TTF at +150mV (vs. Ag/AgCl), and the reduction of TTF(+) at 0mV were used for the monitoring of the enzyme reactions for the bienzyme and trienzyme configurations, respectively. Experimental variables concerning both the biosensors composition and the working conditions were optimized for each configuration. A good repeatability of the measurements with no need of cleaning or pretreatment of the biosensors was obtained in both cases. After 51 days of use, the GDH/DP biosensor still exhibited 87% of the original sensitivity, while the GK/GPOx/HRP biosensor yielded a 46% of the original response after 8 days. Calibration graphs for glycerol with linear ranges of 1.0x10(-6) to 2.0x10(-5) or 1.0x10(-6) to 1.0x10(-5)M glycerol and sensitivities of 1214+/-21 or 1460+/-34microAM(-1) were obtained with GDH/DP and GK/GPOx/HRP biosensors, respectively. The calculated detection limits were 4.0x10(-7) and 3.1x10(-7)M, respectively. The biosensors exhibited a great sensitivity with no significant interferences in the analysis of wines. The biosensors were applied to the determination of glycerol in 12 different wines and the results advantageously compared with those provided by a commercial enzyme kit.
...
PMID:Integrated multienzyme electrochemical biosensors for the determination of glycerol in wines. 1826 15