Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:1.4.1.2 (glutamate dehydrogenase)
4,380 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

An amperometric assay based on urease inactivation has been developed for the screening of heavy metals in environmental samples. The enzyme urease catalyses the hydrolysis of urea and the formation of NH(4)(+) is determined using a NADH-glutamate dehydrogenase coupled reaction system. NADH consumption is monitored amperometrically using screen-printed three electrode configuration and its oxidation current is then correlated to urease activity. The presence of heavy metals in the samples inhibits the urease activity, resulting in a lower NH(4)(+) production and therefore a decrease in NADH oxidation. The use of metallised carbon electrodes gave a decrease in NADH oxidation potential from +300 mV versus Ag/AgCl compared with > +600 mV for bare carbon electrodes, and thus minimised interferences from oxidizable species present in the samples. Electrodes fouling and possible contamination after reuse and cleaning was also eliminated by using screen-printed disposable electrodes. The linear range obtained for Hg(II) and Cu(II) was 10-100 microgl(-1) with a detection limit of 7.2 microgl(-1) and 8.5 microgl(-1), respectively. Cd(II) and Zn(II) produced enzyme inhibition in the range 1-30 mgl(-1), with limits of detection of 0.3 mgl(-1) for Cd(II) and 0.2 mgl(-1) for Zn(II). Pb(II) did not inactivate the urease enzyme significantly at the studied range (up to 50 mgl(-1)). Coefficients of variation (CV) values were 6-9% in all cases. Application of the assay system to leachate samples gave reliable and accurate toxicity assessments when compared to atomic absorption spectrometry (AAS) and inductively coupled plasma atomic emission spectroscopy (ICP-MS) analysis. This approach provides to be a simple and rapid (15 min, including enzyme inhibition time) method for metal ions detection.
...
PMID:Development of urease and glutamic dehydrogenase amperometric assay for heavy metals screening in polluted samples. 1504 46

A screen-printed three-electrode amperometric biosensor based on urease and the nicotinamide adenine dinucleotide hydrogen (NADH)-glutamic dehydrogenase system was developed and applied to the screening of heavy metals in environmental samples. The development of an amperometric sensor for the monitoring of urease activity was feasible by coupling the urea breakdown reaction catalysed by urease to the reductive ammination of ketoglutarate catalysed by glutamic dehydrogenase (GLDH). The ammonia provided by the urea conversion is required for the conversion of ketoglutarate to glutamate with the concomitant oxidation of the NADH cofactor. NADH oxidation is monitored amperometrically at 0.3 V (vs. Ag/AgCl) after urease immobilization onto the screen-printed three-electrode configuration. Immobilization of urease on the surface of screen-printed electrodes was performed by entrapment in alginate gel and adsorption on the electrode in a nafion film. Low sensitivity to inactivation by metals was recorded after urease entrapment in alginate gel with detection limits of 2.9 and 29.8 mg L(-1) for Hg(II) and Cu(II), respectively. The use of the negatively charged nafion film created a more concentrated environment of cations in proximity to the enzyme, thus enhancing the urease inhibition when compared to gel entrapment. The calculated detection limits were 63.6 and 55.3 microg L(-1) for Hg(II) and Cu(II), respectively, and 4.3 mg L(-1) for Cd(II). A significant urease inactivation was recorded in the presence of trace amounts of metals (microg L(-1)) when the enzyme was used free in solution. Analysis of water and soil samples with the developed nafion-based sensor produced inhibition on urease activity according to their metal contents. The obtained results were in agreement with the standard methods employed for sample analysis. Nevertheless, the use of the amperometric assay (with free urease) proved more feasible for the screening of trace amounts of metals in polluted samples.
...
PMID:Urease-glutamic dehydrogenase biosensor for screening heavy metals in water and soil samples. 1530 Mar 52