Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:1.13.12.5 (aequorin)
1,451 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A solid-phase assay for the activity of CMPNeuAc:Gal beta 1-4GlcNAc-R alpha-2,6-sialyltransferase (2,6ST) has been developed. In the assay an acceptor glycoprotein is immobilized onto microtiter plate wells. The two glycoprotein acceptors used were asialofetuin (ASF), which contains oligosaccharides terminating in the sequence Gal beta 1-4GlcNAc-R, and a neoglycoprotein of bovine serum albumin containing covalently attached Gal beta 1-4GlcNAc-R units. Samples containing the donor CMPNeuAc and the 2,6ST were incubated with the immobilized acceptor to generate the product NeuAc alpha 2-6Gal beta 1-4GlcNAc-R. The product was detected by a biotin-streptavidin system using the biotinylated plant lectin Sambucus nigra agglutinin (SNA), which binds to sialic acid in alpha-2,6, but not in alpha-2,3, linkage. The biotinylated SNA bound to the product was then detected with streptavidin and biotinylated forms of either alkaline phosphatase or the recombinant bioluminescent protein aequorin. The assay was optimized with respect to the commercially available 2,6ST and shown to be dependent on the concentration of acceptor and CMPNeuAc and proportional to the 2,6ST activity in the range of 20 to 400 microU in a 1-h assay. The solid-phase assay also allows for the selective detection of 2,6ST activity in human and fetal bovine serum, where the activity was proportional in the range of 0.1 to 2 microliters of serum.
...
PMID:A solid-phase assay for the activity of CMPNeuAc:Gal beta 1-4GlcNAc-R alpha-2,6-sialyltransferase. 128 7

We have developed a sensitive and simple method for assaying glycosyltransferase activities. This method makes use of solution-phase transferase reactions followed by capture to a microplate well coated with a substrate-specific monoclonal antibody. Sugar incorporation is quantitated by binding a saccharide-specific lectin and using bioluminescent aequorin for a reporter molecule. We demonstrate this method using the glycoprotein hormone-specific GalNAc-transferase and its acceptor substrate, agalacto-hCG. As little as 20 ng of agalacto-hCG with 32 nU of GalNAc-transferase gives a detectable signal with less than 10% of the acceptor sites substituted. In addition to this high sensitivity, by doing the transferase reactions in solution, we can assay up to 10 micrograms of agalacto-hCG. We show that this allows the determination of Km and Vmax kinetic constants that compare well to those obtained with radiolabeled nucleotide sugars.
...
PMID:A microplate assay for analysis of solution-phase glycosyltransferase reactions: determination of kinetic constants. 181 92

We have developed a sensitive and rapid solid-phase assay for the serum enzyme UDPGal:beta-D-GlcNAc beta-1,4-galactosyltransferase (beta 1,4-GT) (EC 2.4.1.38) that employs the recombinant bioluminescent protein aequorin as the enzyme label for product detection. The substrate for beta 1,4-GT is a neoglycoprotein, bovine serum albumin containing covalently attached GlcNAc residues (GlcNAc-BSA), and it was immobilized by adsorption in microtiter plate wells. Serum samples were added to each well along with saturating levels of UDPGal and Mn2+. Galactosylation of the neoglycoprotein acceptor by the serum beta 1,4-GT produces the N-acetyllactosamine derivative Gal beta 1, 4GlcNAc-BSA. The product formed is quantified by adding the biotinylated plant lectin Ricinus communis agglutinin-I, which binds specifically to N-acetyllactosamine, followed by the addition of streptavidin and the biotinylated aequorin. Aequorin produces a flash of light in response to Ca2+ and is detectable to 10(-19) mol in a luminometer. Using this assay, the beta 1,4-GT activity in human serum and the activity of a semipurified beta 1,4-GT are linear with time and serum concentration over a wide range. The reaction is dependent on UDPGal and Mn2+, is highly reproducible with a low background, and can be performed in a few hours. Assays employing aequorin have a wider range of linearity than those employing horseradish peroxidase as an enzyme label. These results demonstrate that the assay for beta 1,4-GT is useful for determining activity in heterogeneous samples and also demonstrate the utility of the recombinant protein aequorin for solid-phase assay methods.
...
PMID:A solid-phase assay for beta-1,4-galactosyltransferase activity in human serum using recombinant aequorin. 190 13

The recombinant photoprotein aequorin was used as a reporter in highly sensitive and automatable hybridization assays for the analysis of transgenic sequences in genetically modified organisms (GMO). The terminator of the nopaline synthase gene (NOS) from Agrobacterium tumefaciens and the 35S promoter sequence were detected in genetically modified soybean. The endogenous, soybean-specific, lectin gene was also detected for confirmation of the integrity of extracted DNA. A universal detection reagent was produced through conjugation of aequorin to the oligonucleotide (dA)(30). Biotinylated (through PCR) products for the three target sequences were captured onto streptavidin-coated wells, and one strand was removed by NaOH treatment. The immobilized single-stranded DNAs were then hybridized with oligonucleotide probes consisting of a target-specific segment and a poly(dT) tail. This allowed the subsequent determination of all hybrids through the use of the (dA)(30)-aequorin conjugate as a universal reagent. The bound aequorin was measured by adding Ca(2+) and integrating the light emission for 3 s. As low as 2 pM (100 amol per well) of amplified DNA was detectable for all three targets, with a signal-to-background ratio of about 2. The analytical range extended up to 2000 pM. As low as 0.05% GMO content in soybean can be detected with a signal-to-background ratio of 8.2. The overall repeatability of the proposed assay, including DNA extraction, PCR, and hybridization assay, ranged from 7.5-19.8%. The use of a (dA)(30)-aequorin conjugate renders the assay configuration general for any target DNA, provided that the specific probe carries a poly(dT) tail.
...
PMID:Detection of transgenes in soybean via a polymerase chain reaction and a simple bioluminometric assay based on a universal aequorin-labeled oligonucleotide probe. 1496 25

Quantitative competitive polymerase chain reaction (PCR), especially the double competitive PCR methods (DC-PCR), have evolved as reliable approaches to quantification of genetically modified organisms (GMO) in food. However, DC-PCR is a low-throughput method because it requires titration of each sample with various amounts of a competitive internal standard, a protocol that involves several PCRs per sample followed by electrophoresis and densitometry. To address this drawback, we have developed a new method for GMO quantification, namely, a high-throughput double quantitative competitive PCR (HT-DCPCR). In HT-DCPCR, electrophoresis and densitometry are replaced by a rapid, microtiter well-based bioluminometric hybridization assay and there is no need for titration of each sample. The determination of GM soya was chosen as a model. We have constructed internal standards (DNA competitors) both for the 35S promoter sequence and for a plant-specific reference gene (lectin). The competitors have identical size and share the same primer binding sites with the target sequences but differ in a 24-bp internal segment. Each target sequence (35S and lectin) is coamplified with a constant amount (1000 copies) of the respective competitor. The four amplified fragments are hybridized with specific probes and captured on a universal solid phase to achieve simplicity and high throughput. The hybrids are determined by using streptavidin conjugated to the photoprotein aequorin. The ratio of the luminescence values obtained for the target and the competitor is linearly related to the starting amount of target DNA. The limit of quantification for the 35S promoter is 24 copies. The proposed method was evaluated by determining the GMO content of soybean powder certified reference materials. Also HT-DCPCR was compared to real-time PCR in a variety of real samples.
...
PMID:High-throughput double quantitative competitive polymerase chain reaction for determination of genetically modified organisms. 1605 89