Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:1.10.3.3 (ascorbate oxidase)
778 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The objective of this study was to establish a hepatic lipase (HL) assay method that can be applied to automatic clinical analyzers. Seventy-four hyperlipidemic subjects (men/women 45/29) were recruited. Lipase activity was assayed measuring the increase in absorbance at 546 nm due to quinonediimine dye production. Reaction mixture R-1 contained 50 mM Tris-HCl (pH 9.5), 0.5 mM glycerol-1,2-dioleate, 0.4% (unless otherwise noted) polyoxyethylene-nonylphenylether, 3 mM ATP, 3 mM MgCl(2), 1.5 mM CaCl(2), monoacylglycerol-specific lipase, glycerol kinase, glycerol-3-phosphate oxidase, 0.075% N,N-bis-(4-sulfobutyl)-3-methylaniline-2 Na, peroxidase, ascorbic acid oxidase. Reaction mixture R-2 contained 50 mM Tris-HCl (pH9.5), 0.15% 4-aminoantypirine. Automated assay for activity was performed with a Model 7080 Hitachi analyzer. In the lipase assay, 160 microl of R-1 was incubated at 37 degrees C with 3 microl of samples for 5 min, and 80 microl of R-2 was added. Within-run coefficient of variations was 0.9-1.0%. Calibration curve of lipase activity was linear (r = 0.999) between 0 and 320 U/l. Analytical recoveries of purified HL added to plasma were 96.6-99.8%. HL activity in postheparin plasma measured in this method had a closer correlation with HL mass by a sandwich ELISA (r = 0.888, P < 0.0001) than those in the conventional method using [(14)C-]triolein (r = 0.730, P < 0.0001). This assay method for HL activity can be applied to an automatic clinical analyzer.
...
PMID:A novel method for measuring human hepatic lipase activity in postheparin plasma. 1709 Jun 61

The objective of this study was to establish a new lipoprotein lipase (LPL) and hepatic lipase (HL) activity assay method. Seventy normal volunteers were recruited. Lipase activities were assayed by measuring the increase in absorbance at 546 nm due to the quinoneine dye. Reaction mixture-1 (R-1) contained dioleoylglycerol solubilized with lauryldimethylaminobetaine, monoacylglycerol-specific lipase, glycerolkinase, glycerol-3-phosphate oxidase, peroxidase, ascorbic acid oxidase, and apolipoprotein C-II (apoC-II). R-2 contained Tris-HCl (pH 8.7) and 4-aminoantipyrine. Automated assay of lipase activities was performed with an automatic clinical analyzer. In the assay for HL + LPL activity, 160 microl R-1 was incubated at 37 degrees C with 2 microl of sample for 5 min, and 80 microl R-2 was added. HL activities were measured under the same conditions without apoC-II. HL and LPL activities were also measured by the conventional isotope method and for HL mass by ELISA. Lipase activity detected in a 1.6 M NaCl-eluted fraction from a heparin-Sepharose column was enhanced by adding purified apoC-II in a dose-dependent manner, whereas that eluted by 0.8 M NaCl was not. Postheparin plasma-LPL and HL activities measured in the present automated method had high correlations with those measured by conventional activity and mass methods. This automated assay method for LPL and HL activities is simple and reliable and can be applied to an automatic clinical analyzer.
...
PMID:A novel method for measuring human lipoprotein lipase and hepatic lipase activities in postheparin plasma. 1834 10